Lead flashing is rolled lead sheet shaped and fixed to weatherproof the junctions of a roof, such as where a roof meets a wall, chimney, dormer cheek, parapet or rooflight, and the edges of flat roofs and gutters. Lead is soft, dense and malleable, so it can be dressed by hand over the profile of tiles and slates and bossed into three-dimensional shapes without joints, and it lasts for many decades. In the United Kingdom, Ireland and much of northern Europe it has long been the standard flashing material on pitched roofs of slate and tile, and on many flat-roof upstands.4
Lead flashing is a sub-topic both of lead roofing, which covers whole roofs of lead, and of roof flashing, which covers flashings of every material. Compared with sheet steel, aluminium or copper flashings, lead is easier to dress to complex shapes on site but heavier, softer and more vulnerable to theft. Compared with cast lead sheet, the flashing material used today is almost always milled (rolled) lead made to BS EN 12588.1
Material and lead codes
Rolled lead in Britain is ordered by code number, a system based originally on weight in pounds per square foot (see lead sheet codes).7 Lead Sheet Association guidance, as quoted in a Local Authority Building Control (LABC) article, gives code 4 as the minimum for cover flashings and code 3 as the minimum for soakers, with heavier codes in exposed positions; another handbook allows code 3 only for soakers in sheltered locations.2 Codes 5 to 8 are used for heavier work such as gutters, aprons on exposed sites, dormers and flat roofs.
Lead expands and contracts with temperature about three times as much as steel, so if a piece is too long or restrained it can buckle, fatigue and split.7 For this reason individual flashing pieces are normally limited to 1.5 m (5 ft) in length, and to 1 m (3.3 ft) where the lead is bonded continuously along one edge to asphalt, bituminous felt or single-ply membrane.13
Types of lead flashing
- Cover flashing. A flashing turned into a mortar joint above a roof or upstand and dressed down over the top of it, shedding water that runs down the wall away from the junction. Flat-roof perimeters are usually finished with cover flashings over the membrane upstand, similar to North American counter flashing.4
- Stepped flashing. At a pitched roof abutting a wall, the top edge of the flashing is cut in steps that follow the brick courses, each step turned into a bed joint, while the lower edge is dressed over the roof covering or over soakers.4
- Soakers. Small L-shaped pieces interleaved with each course of slates or plain tiles, with an upstand against the wall, covered by a stepped cover flashing. See lead soakers. LABC guidance says soakers should be about the same length as the slate and fitted over the tile beneath so that the fixings of the tile above do not puncture them.2
- Secret gutter. A concealed lead channel beside an abutment, used with flat tiles.4
- Apron flashing. A flashing across the lower side of a chimney or the top of a lean-to roof where it meets a wall, turned into the wall and dressed down over the tiles below. See apron flashing.
- Chimney flashings. A set comprising a front apron, side step flashings and soakers, and a back gutter, often with a cricket or saddle behind wide stacks. See chimney flashing.
- Flashings at rooflights, dormers and penetrations, including bossed or welded collars around pipes.
Different roof coverings need different details: slates and plain tiles take soakers and step flashings; profiled single-lap tiles need step and cover flashings dressed over their profile; and flat tiles use secret gutters.4
Fixing into masonry
The top edge of a lead flashing is turned into a raked-out mortar joint (sometimes called a raglet or chase) and secured. Building conservation guidance calls for a turn-in of at least 25 mm (1 in), held by lead wedges at no more than 450 mm (18 in) centres, and warns against folding back the edge of the lead inside the joint, which prevents the pointing bonding.4 A manufacturer's fitting guide similarly requires mortar to be raked out to at least 25 mm, with proprietary clips at no more than 450 mm centres and at least one per step on stepped flashings.3 In very thin joints of 4 to 8 mm, a groove about 12 mm wide and 25 mm deep can be cut instead; in joints wider than about 18 mm, the lead is turned up a raggle and fixed with stainless steel screws and washers at about 450 mm centres, because wedges in wide joints can work loose with wind and temperature changes.4 The joint is then repointed with mortar or a lead sealant, which should be at least 10 mm (0.4 in) deep in the joint.34
Lengths are lapped at least 100 mm (4 in) end to end.4 On flat and pitched lead work generally, laps depend on pitch and exposure: about 75 mm (3 in) on vertical work, 150 mm (6 in) at 30°, and up to about 395 mm (15.5 in) at low pitches.1 Free edges are restrained against wind by clips of copper (quarter-hard temper, at least 0.6 mm thick) or stainless steel (at least 50 mm wide and 0.38 mm thick) at 300 to 500 mm centres, each turned at least 25 mm over the edge; lead clips are not recommended in moderate or severe exposure.4
Where lead is built into mortar more than 50 mm (2 in) from the face of a wall, as in cavity trays and damp-proof courses, it should be coated on both sides with bitumen paint to protect it from alkali and sulphate attack from the mortar.14
Dressing and bossing
Once fixed, the lead is dressed down tightly over the roof covering with a wooden dresser so that it follows the profile of tiles and slates and resists wind lift. Internal and external corners are formed by bossing: working the soft lead with boxwood or plastic tools so that it stretches and thickens into a seamless shape. Where shapes are too complex or the lead too thick to boss, joints are made by lead welding.
Patination oil
When new lead becomes wet it forms a soluble white lead carbonate that rain can wash onto adjacent tiles, brick, stone or glazing, leaving pale stains. Patination oil, a spirit-based surface treatment brushed onto new lead, prevents the carbonate forming and so reduces staining.5 Over time the lead develops a protective surface film of lead carbonate.7
Performance and failure modes
Correctly specified, fixed and dressed lead flashings can last more than 100 years.4 Common failures include:
- Splitting and cracking from over-long pieces, excessive restraint or too thin a code.17
- Wind lift where free edges are not clipped or are dressed loosely.4
- Loose turn-ins where wedges or pointing fail, letting water run behind the flashing.4
- Poor abutment details, such as flashings chased into rendered walls and run under the tiles without soakers, which can let rain running down the wall get behind the lead or be drawn through laps by capillary action.2
- Corrosion from acids in run-off from lichen, rotting leaves, bird droppings and oak shingles, and from alkalis and sulphates where lead is built deep into mortar.71
- Theft, which leaves walls and roofs open to rain.6
Theft and alternatives
Lead's scrap value makes it a target, especially on churches and other public buildings, and losses can cause serious water damage to masonry and timber.6 Historic Scotland recommends improving security first, through alarms, forensic marking, anti-climb paint and careful control of scaffolding, and generally expects like-for-like replacement where lead contributes to a building's character, while accepting other materials where lead is hidden from view and theft is likely to recur.6
Regional practice
Lead flashings are traditional in Britain, Ireland, the Netherlands, Belgium, Scandinavia and parts of Germany and France, and are found on historic buildings across Europe and in older North American cities. In North America, new construction mostly uses galvanised steel, aluminium or copper step flashing.
Sources
Reviewed 2 November 2026 · 7 sources · 7 cited inline · Editorial policy · Plain-text version · Suggest a correction
- The top ten dos and don'ts of rolled lead sheetRIBA Journal · ribaj.com
- How to get it right: too much abutment flashingLABC · labc.co.uk
- BLM Rolled Lead Sheet: Fixing FlashingsBritish Lead · specifiedby.com
- The Ins and Outs of Weathering to WallsThe Building Conservation Directory · buildingconservation.com
- Patination OilFuturebuild · futurebuild.co.uk
- Lead Theft: Guidance on Protecting Traditional Buildings (Short Guide, 2nd ed., 2015)Historic Scotland · app-hes-pubs-prod-neu-01.azurewebsites.net
- Church LeadworkThe Building Conservation Directory · buildingconservation.com