High-Temperature Underlayment

Also known as HT underlayment · high-temp ice and water shield · high-temperature ice barrier · HT self-adhered underlayment · metal roof peel-and-stick underlayment

High-temperature underlayment is a self-adhered waterproofing membrane formulated to withstand sustained roof-deck temperatures of about 250-265 F (121-129 C) under metal and tile roofs without softening or flowing.

4 min read6 sourcesNorth America
Cite this entry"High-Temperature Underlayment." roof.wiki. https://roof.wiki/high-temperature-underlayment/ (accessed 2026-11-03).
Typical temperature rating
About 250-265 F (121-129 C)
Main uses
Under metal panels and shingles, clay and concrete tile
Chemistries
High-softening-point polymer-modified bitumen (SBS or rubberized asphalt) or butyl
Test standard
ASTM D1970 (self-adhering underlayment)
Example thickness
40 mil (1.02 mm)
UV exposure limits (examples)
120-180 days before covering
Slip sheet
Rosin paper or smooth synthetic under moving metal panels

High-temperature underlayment, often shortened to HT underlayment, is a self-adhering waterproof membrane designed for use beneath roof coverings that run very hot, chiefly metal panels and shingles and clay or concrete tile. It performs the same role as an ordinary self-adhered ice and water barrier — sealing around fasteners and protecting eaves, valleys and other vulnerable areas, or the whole deck — but its adhesive and top film are formulated to stay stable at temperatures that would make standard asphalt membranes soften and flow.12 Products are typically rated for service up to about 250-265 F (121-129 C).13

Under the parent topic of roofing underlayment, HT membranes are a specialised branch of self-adhered underlayments (see self-adhered membrane), distinct from mechanically fastened felts and synthetic underlayments, and from ordinary granular-surfaced ice barriers made for use under asphalt shingles.

Why metal and tile need them

Sunlit metal panels transfer heat directly to whatever lies beneath. Florida contractor training material puts underlayment temperatures beneath sunlit metal at about 200-250 F (93-121 C), compared with a softening range of roughly 160-180 F (71-82 C) for standard asphaltic ice-and-water membranes.4 Under those conditions a standard membrane can:

  • soften and bleed asphalt out of laps and drip into soffits and eaves;4
  • bond to the underside of the metal, so that when the panels expand and contract the underlayment tears and the roof pops and groans with each temperature change;4
  • stain or attack some metals; one manufacturer advises against its asphaltic HT membrane under copper, weathering steel and zinc at high altitude.1

Tile roofs, particularly adhered or foam-set tile in hot climates, create similar heat and require underlayments that will not deform beneath the tile or its adhesive. Some HT products are made specifically for adhesive-bonded and mechanically attached concrete and clay tile.26

Pans (concave) are laid first and carry the water.Covers (convex) sit over the joints between them.Each course overlaps the one below up the slope.
How pan and cover tiles shed water

Materials and specifications

HT underlayments are made in two main chemistries:

  • High-temperature polymer-modified bitumen — rubberized asphalt or SBS-modified bitumen with a high softening point, faced with a polymer film or a reinforcing mat;123
  • Butyl-based adhesives — non-asphaltic, used where asphalt is unsuitable; one manufacturer recommends its butyl-based membrane instead of its asphaltic HT product under copper, weathering steel (Cor-Ten) and zinc roofs at high altitude.14

Published examples show the typical range:123

  • a 40 mil (1.02 mm) rubberized asphalt membrane with a UV-resistant polymer film, rated to 260 F (127 C), flexible at -20 F (-29 C), meeting ASTM D1970, in 36 in (914 mm) wide rolls covering 200 or 225 ft2 (18.6 or 20.9 m2);
  • SBS-modified products rated to 250 F and 265 F, in reinforced (fibreglass mat) and non-reinforced versions, with a 3 in (76 mm) adhesive selvedge and split-release liners;
  • a polyester-reinforced HT tile-and-metal underlayment rated to 250 F (121 C);
  • a fibreglass-reinforced self-adhered metal-roof underlayment rated to 265 F with a 180-day exposure rating.

Reinforced grades add tensile strength and thermal stability, while non-reinforced grades are more conformable and double as flashing membranes at valleys, roof-to-wall transitions, vents and skylights.2 The top surface is usually a textured or slip-resistant film rather than granules, which gives a smooth bed for metal panels and safer footing on steep slopes.23 Like other self-adhered underlayments, HT membranes are tested to ASTM D1970, which covers self-adhering polymer-modified bitumen sheet used as steep-roof underlayment for ice-dam protection; the HT rating itself is a manufacturer's declaration based on its own testing.1

Slip sheets

Because even an HT membrane is tacky, metal-roofing practice calls for a slip sheet between the membrane and standing-seam or other panels that move with temperature. Accepted options are unsaturated rosin paper, traditionally a 5 lb grade, or a smooth non-asphaltic synthetic sheet; without it, hot panels can adhere to the membrane and thermal movement tears the underlayment and makes the roof noisy.4 Some HT products have a non-tacky film surface intended to avoid this, so specifiers follow both the membrane and the metal manufacturer's instructions.1 See rosin paper slip sheet and thermal movement in metal roofs.

Roof deck + underlayment seamer Panel legs stand up at each side— no fasteners through theweathering surface. Clip holds the panel, lets itmove with temperature.Double lock: legs folded 180°twice into a watertight seam.
How a standing seam is formed

Installation

Typical installation follows ordinary self-adhered practice, with HT-specific limits:124

  1. Prepare the deck — clean, dry and smooth; do not apply over old roof coverings or on resinous wood planks that can react with the adhesive.
  2. Observe temperature limits — apply when air, deck and membrane are at about 40 F (5 C) or warmer.
  3. Lay out and peel the split release liner, starting at the eaves, with side and end laps as specified (often a 3 in selvedge).
  4. Cover critical areas — common minimums for metal roofs are a 36 in (914 mm) width at eaves and rakes, 36 in centred in valleys (18 in each side), 12 in (305 mm) up abutting walls, a continuous layer over the ridge, and patches around pipe penetrations.4
  5. Add a slip sheet where the metal manufacturer requires one.
  6. Cover within the exposure limit — 120 days for one HT membrane and 120-180 days for others; HT membranes are not permanent roof surfaces.123

HT membranes are generally incompatible with EPDM, TPO, flexible PVC and polysulfide sealants, and asphaltic versions are not used where their odour would reach occupied interiors.1

Moisture considerations

A fully adhered HT membrane is effectively a vapour retarder at the deck. Over a ventilated roof space that is usually acceptable, but over an unventilated cathedral ceiling, interior moisture can be trapped below it; metal-panel manufacturers note that self-adhered sheets used over the whole roof often act as air and vapour barriers, so roof ventilation and moisture control must be considered.5 Corrosion-sensitive metals such as zinc also need ventilation on their underside (see ventilation under metal roofs and zinc roofing).1

Where HT underlayments are used

HT membranes are standard beneath standing-seam and other metal roofs, stone-coated steel, and tile roofs in North America, especially in the Sun Belt and in snow regions where an ice barrier is required at the eaves under a metal roof.24 They are also used on mansards, valleys and roof-to-wall transitions as flashing membranes, using non-reinforced grades that conform to angles.2

Sources

Reviewed 2 November 2026 · 6 sources · 6 cited inline · Editorial policy · Plain-text version · Suggest a correction

  1. Grace Ice & Water Shield HT data sheetGCP Applied Technologies · gcpat.com
  2. Underlayments for Use in Metal and Tile Roofing SystemsRoofing Magazine · roofingmagazine.com
  3. Roof Underlayments (product roundup)Metal Construction News · metalconstructionnews.com
  4. Metal Roof Flashing, Underlayments and Thermal MovementOpen Exam Prep (Florida roofing contractor study guide) · open-exam-prep.com
  5. Roofer's Choice: High-Temperature UnderlaymentsRoofing Magazine · roofingmagazine.com

From the community

Know this topic first-hand? Share a photo you took, a correction with a source, or local knowledge. Every contribution is reviewed before it appears.

Contribute to High-Temperature Underlayment

Loading…