Foam-adhesive tile setting is a way of attaching clay and concrete roof tiles in which each tile is bedded on one or more "paddies" of polyurethane foam adhesive dispensed onto the underlayment, instead of being bedded in mortar or held only by nails, screws or clips. The foam expands and cures to bond the tile to the waterproofed deck, producing a more monolithic roof that resists wind uplift with few or no fastener holes through the underlayment.12 The method is closely tied to Florida, where it was developed after Hurricane Andrew in 1992 and where it is now set out in the industry's high-wind tile installation manual.34
It is one of three main attachment methods covered under clay and concrete tile installation: mechanical fastening (nails or screws, often with tile clips and battens), mortar setting, and adhesive setting. Hybrid systems combine foam with fasteners.
Background
Before the 1990s many Florida tile roofs were mortar-set, with tiles bedded in mortar on the underlayment. Hurricane Andrew in 1992 caused widespread failures of these mortar-set tiles on low-pitched roofs, and the tile industry responded by developing other attachment methods, including foam adhesives and improved mechanical fixing, which the Florida code later accepted.4 Polyurethane adhesive makers introduced roof-tile foams after Andrew and set up their own installer certification.4
After the 2004 hurricanes, a FEMA survey found that mortar-set tiles had suffered much larger blow-off areas than tiles fixed with foam or mechanical fasteners. Properly foamed tiles generally performed well in Hurricane Charley, with the rake edges being the main weak point.4 Since then the use of polyurethane tile adhesives has kept growing in the Florida market.2
Materials
Two kinds of product are used:12
- Single-component foams cure by reacting with moisture in the air and on the surfaces they touch, so their performance depends more on temperature and humidity. Cans are shaken before use.
- Two-component foams are mixed at the gun or nozzle and cure chemically, so they are less sensitive to humidity. They must be calibrated before and during application. Large pressurised two-component systems usually give the highest published uplift values when used with large paddies, and can lower the adhesive cost per tile when used with medium paddies.2
The FRSA–TRI manual requires polyurethane tile foams to be tested for density (ASTM D1622), compressive strength (D1621), tensile strength (D1623), water absorption (D2842), vapour transmission (E96), dimensional stability (D2126), closed-cell content (D2856), surface burning (E84) and roof-covering fire performance (E108). Structural bonding adhesives must meet ASTM D3498.3
Each product must hold a Florida Product Approval or, in Miami-Dade County, a Miami-Dade Notice of Acceptance, and the number is usually printed on the package.12 See Florida Product Approval and Miami-Dade NOA.
The governing manual
In Florida, tile attachment follows the Florida High Wind Concrete and Clay Roof Tile Installation Manual, produced by a joint committee of the Tile Roofing Industry Alliance (TRI) and the Florida Roofing and Sheet Metal Contractors Association (FRSA). The 6th edition is dated 2020 and is itself held as a Florida product installation document.3
The manual's approach is to compare the aerodynamic uplift moment on each tile with the allowable moment of the chosen attachment. The uplift moment is calculated from the design wind pressure, tile dimensions and a lift coefficient, as set out in the manual. For foam and mortar it refers users to the uplift values in each manufacturer's product approval rather than giving generic tables.3
Slope limits and supplementary fastening
The manual's tables list adhesive attachment with single-ply self-adhered underlayments and two-ply underlayment systems (cold-applied, heat-applied, hot-mopped or self-adhered) on pitches from 3:12 upward.3 Its fastening rules for adhesive-set field tiles are:3
- 2:12 up to and including 6:12: no fasteners needed in addition to the adhesive.
- Over 6:12 to 7:12: fasten the first course, and every third tile in every fifth course, in addition to the adhesive.
- Over 7:12: fasten every tile in addition to the adhesive.
- On battens, tiles with protruding anchor lugs need no extra fastening beyond the adhesive.
On steep roofs, fasteners stop tiles creeping downslope under their own weight while the foam provides the uplift resistance (see tile slippage).
Installation
- Underlayment. The tile underlayment is installed and inspected first; the foam bonds to its top surface, so it must be clean, dry and of a type the adhesive maker approves.3
- Paddy placement. The foam maker's drawings show the size and position of the paddies or beads for each tile profile, and these differ between flat, low and high profiles. Field, eave and hip-and-ridge tiles can need very different amounts and positions.1 For two-piece barrel tile, one article describes a foam pad under the pan tile and a double pad under the overlapping cap; in wind zones above 110 mph (177 km/h) it gives a pad of 1 × 1 × 8 in (25 × 25 × 203 mm).4
- Placing the tile. The tile must be set into the foam within its open time, typically one to four minutes, before the foam skins over. Foam that has started to cure will not reach the design uplift and must be removed and reapplied.12
- Checking contact. Some makers specify a minimum contact area in square inches and recommend lifting a set number of tiles to check it.1
- Hips and ridges. Foam can serve both as the structural attachment and as the weather block where field tiles meet a ridge or hip support, which can be metal, plastic or wood. The foam must touch both the underside of the tile and the support member, and exposed foam needs a compatible coating against ultraviolet light.3 Starter tiles are secured at both ends with fasteners, mortar or adhesive.3
Applicators must be trained and certified by a qualified trainer, usually the adhesive manufacturer or a certified distributor, because both Florida Product Approvals and Miami-Dade NOAs require installation by certified applicators following the manufacturer's instructions.12
Comparison with other methods
- Versus mortar setting. Foam is much stronger than mortar in uplift and far lighter.4 Hip and ridge tiles take much less time with foam than with a full mortar bed.2 Florida still allows mortar as a structural attachment where it is factory-premixed and product-approved, but job-mixed mortar is limited to cosmetic use and weather blocking.3
- Versus mechanical fastening. Foam needs few or no holes through the underlayment and avoids cracking tiles by overdriving fasteners. Field tiles can be set in a fraction of the time it takes to fasten them.12
- Weak points. Foam roofs depend entirely on workmanship that cannot be checked once the tile is down. After Hurricane Charley, some failed foam-set roofs had too little foam, foam in the wrong place or both, because installers had not followed instructions; some makers required those installers to be recertified.4
Hurricane performance
Tile roofs that fail in hurricanes usually fail first at hips, ridges, rakes and eaves rather than in the field. FEMA's Mitigation Assessment Team after Hurricane Irma in 2017 found damage to concrete and clay tile concentrated at hips and ridges and at rake and eave edges, as with other roof coverings.5 The 2004 experience pointed the same way, with rake details the main weakness on otherwise well-foamed roofs.4 For this reason, current practice pays particular attention to the foam or mechanical attachment of hip, ridge and rake tiles.3
Where it is used
Foam-adhesive setting is used mainly in Florida, and to a lesser extent in other US hurricane-prone coastal states, the Caribbean and similar high-wind regions where heavy tile roofs are common.24 Elsewhere, clay and concrete tiles are usually fixed mechanically, with clips, nails or screws, and mortar-bedded or dry-fix ridges (see BS 5534).
On the timeline
- 1990sBefore the 1990s many Florida tile roofs were mortar-set, with tiles bedded in mortar on the underlayment.
- 1992The method is closely tied to Florida, where it was developed after Hurricane Andrew in 1992 and where it is now set out in the industry's high-wind tile installation manual.
- 2004After the 2004 hurricanes, a FEMA survey found that mortar-set tiles had suffered much larger blow-off areas than tiles fixed with foam or mechanical fasteners.
- 2017FEMA's Mitigation Assessment Team after Hurricane Irma in 2017 found damage to concrete and clay tile concentrated at hips and ridges and at rake and eave edges, as with other roof coverings.
Sources
Reviewed 2 November 2026 · 5 sources · 5 cited inline · Editorial policy · Plain-text version · Suggest a correction
- Tips for Successful Use of Foam Tile AdhesivesFlorida Roofing and Sheet Metal Contractors Association · floridaroof.com