# High-Temperature Underlayment

> High-temperature underlayment is a self-adhered waterproofing membrane formulated to withstand sustained roof-deck temperatures of about 250-265 F (121-129 C) under metal and tile roofs without softening or flowing.

- URL: https://roof.wiki/high-temperature-underlayment/
- Topic: Roof Components
- Also known as: HT underlayment; high-temp ice and water shield; high-temperature ice barrier; HT self-adhered underlayment; metal roof peel-and-stick underlayment
- Regions: North America
- First published: 2026-11-02 · Last reviewed: 2026-11-02
- Cite as: "High-Temperature Underlayment." roof.wiki. https://roof.wiki/high-temperature-underlayment/

## Key facts

- **Typical temperature rating:** About 250-265 F (121-129 C)
- **Main uses:** Under metal panels and shingles, clay and concrete tile
- **Chemistries:** High-softening-point polymer-modified bitumen (SBS or rubberized asphalt) or butyl
- **Test standard:** ASTM D1970 (self-adhering underlayment)
- **Example thickness:** 40 mil (1.02 mm)
- **UV exposure limits (examples):** 120-180 days before covering
- **Slip sheet:** Rosin paper or smooth synthetic under moving metal panels

**High-temperature underlayment**, often shortened to **HT underlayment**, is a self-adhering waterproof membrane designed for use beneath roof coverings that run very hot, chiefly metal panels and shingles and clay or concrete tile. It performs the same role as an ordinary self-adhered [ice and water barrier](https://roof.wiki/ice-and-water-shield/) — sealing around fasteners and protecting eaves, valleys and other vulnerable areas, or the whole deck — but its adhesive and top film are formulated to stay stable at temperatures that would make standard asphalt membranes soften and flow.[1][2] Products are typically rated for service up to about 250-265 F (121-129 C).[1][3]

Under the parent topic of [roofing underlayment](https://roof.wiki/roofing-underlayment/), HT membranes are a specialised branch of self-adhered underlayments (see [self-adhered membrane](https://roof.wiki/self-adhered-membrane/)), distinct from mechanically fastened felts and [synthetic underlayments](https://roof.wiki/synthetic-underlayment/), and from ordinary granular-surfaced ice barriers made for use under asphalt shingles.

## Why metal and tile need them

Sunlit metal panels transfer heat directly to whatever lies beneath. Florida contractor training material puts underlayment temperatures beneath sunlit metal at about 200-250 F (93-121 C), compared with a softening range of roughly 160-180 F (71-82 C) for standard asphaltic ice-and-water membranes.[4] Under those conditions a standard membrane can:

- **soften and bleed** asphalt out of laps and drip into soffits and eaves;[4]
- **bond to the underside of the metal**, so that when the panels expand and contract the underlayment tears and the roof pops and groans with each temperature change;[4]
- **stain or attack** some metals; one manufacturer advises against its asphaltic HT membrane under copper, weathering steel and zinc at high altitude.[1]

Tile roofs, particularly adhered or foam-set tile in hot climates, create similar heat and require underlayments that will not deform beneath the tile or its adhesive. Some HT products are made specifically for adhesive-bonded and mechanically attached concrete and clay tile.[2][6]

## Materials and specifications

HT underlayments are made in two main chemistries:

- **High-temperature polymer-modified bitumen** — rubberized asphalt or SBS-modified bitumen with a high softening point, faced with a polymer film or a reinforcing mat;[1][2][3]
- **Butyl-based adhesives** — non-asphaltic, used where asphalt is unsuitable; one manufacturer recommends its butyl-based membrane instead of its asphaltic HT product under copper, weathering steel (Cor-Ten) and zinc roofs at high altitude.[1][4]

Published examples show the typical range:[1][2][3]

- a 40 mil (1.02 mm) rubberized asphalt membrane with a UV-resistant polymer film, rated to 260 F (127 C), flexible at -20 F (-29 C), meeting ASTM D1970, in 36 in (914 mm) wide rolls covering 200 or 225 ft2 (18.6 or 20.9 m2);
- SBS-modified products rated to 250 F and 265 F, in reinforced (fibreglass mat) and non-reinforced versions, with a 3 in (76 mm) adhesive selvedge and split-release liners;
- a polyester-reinforced HT tile-and-metal underlayment rated to 250 F (121 C);
- a fibreglass-reinforced self-adhered metal-roof underlayment rated to 265 F with a 180-day exposure rating.

Reinforced grades add tensile strength and thermal stability, while non-reinforced grades are more conformable and double as flashing membranes at valleys, roof-to-wall transitions, vents and skylights.[2] The top surface is usually a textured or slip-resistant film rather than granules, which gives a smooth bed for metal panels and safer footing on steep slopes.[2][3] Like other self-adhered underlayments, HT membranes are tested to **ASTM D1970**, which covers self-adhering polymer-modified bitumen sheet used as steep-roof underlayment for ice-dam protection; the HT rating itself is a manufacturer's declaration based on its own testing.[1]

## Slip sheets

Because even an HT membrane is tacky, metal-roofing practice calls for a **slip sheet** between the membrane and standing-seam or other panels that move with temperature. Accepted options are unsaturated rosin paper, traditionally a 5 lb grade, or a smooth non-asphaltic synthetic sheet; without it, hot panels can adhere to the membrane and thermal movement tears the underlayment and makes the roof noisy.[4] Some HT products have a non-tacky film surface intended to avoid this, so specifiers follow both the membrane and the metal manufacturer's instructions.[1] See [rosin paper slip sheet](https://roof.wiki/rosin-paper-slip-sheet/) and [thermal movement in metal roofs](https://roof.wiki/thermal-movement-in-metal-roofs/).

## Installation

Typical installation follows ordinary self-adhered practice, with HT-specific limits:[1][2][4]

1. **Prepare the deck** — clean, dry and smooth; do not apply over old roof coverings or on resinous wood planks that can react with the adhesive.
2. **Observe temperature limits** — apply when air, deck and membrane are at about 40 F (5 C) or warmer.
3. **Lay out and peel** the split release liner, starting at the eaves, with side and end laps as specified (often a 3 in selvedge).
4. **Cover critical areas** — common minimums for metal roofs are a 36 in (914 mm) width at eaves and rakes, 36 in centred in valleys (18 in each side), 12 in (305 mm) up abutting walls, a continuous layer over the ridge, and patches around pipe penetrations.[4]
5. **Add a slip sheet** where the metal manufacturer requires one.
6. **Cover within the exposure limit** — 120 days for one HT membrane and 120-180 days for others; HT membranes are not permanent roof surfaces.[1][2][3]

HT membranes are generally incompatible with EPDM, TPO, flexible PVC and polysulfide sealants, and asphaltic versions are not used where their odour would reach occupied interiors.[1]

## Moisture considerations

A fully adhered HT membrane is effectively a vapour retarder at the deck. Over a ventilated roof space that is usually acceptable, but over an unventilated cathedral ceiling, interior moisture can be trapped below it; metal-panel manufacturers note that self-adhered sheets used over the whole roof often act as air and vapour barriers, so roof ventilation and moisture control must be considered.[5] Corrosion-sensitive metals such as zinc also need ventilation on their underside (see [ventilation under metal roofs](https://roof.wiki/ventilation-under-metal-roofs/) and [zinc roofing](https://roof.wiki/zinc-roofing/)).[1]

## Where HT underlayments are used

HT membranes are standard beneath standing-seam and other metal roofs, [stone-coated steel](https://roof.wiki/stone-coated-steel/), and tile roofs in North America, especially in the Sun Belt and in snow regions where an ice barrier is required at the eaves under a metal roof.[2][4] They are also used on mansards, valleys and roof-to-wall transitions as flashing membranes, using non-reinforced grades that conform to angles.[2]

## Sources

1. Grace Ice & Water Shield HT data sheet — GCP Applied Technologies. https://gcpat.com/sites/gcpat.com/files/2017-07/RE0059_GIWS-210-0316_GIWS-HT_DataSheet_LoRes.pdf
2. Underlayments for Use in Metal and Tile Roofing Systems — Roofing Magazine. https://roofingmagazine.com/underlayments-for-use-in-metal-and-tile-roofing-systems/
3. Roof Underlayments (product roundup) — Metal Construction News. https://www.metalconstructionnews.com/?p=4428
4. Metal Roof Flashing, Underlayments and Thermal Movement — Open Exam Prep (Florida roofing contractor study guide). https://open-exam-prep.com/study-guides/fl-roofing-contractor/ch7/metal-flashing-underlayment
5. Roofing Underlayment and Its Attachment Requirements — MBCI. https://www.mbci.com/tag/irc/
6. Roofer's Choice: High-Temperature Underlayments — Roofing Magazine. https://roofingmagazine.com/roofers-choice-high-temperature-underlayments/