A base sheet is the first, lowest layer of a multi-ply bituminous roof membrane: the sheet laid directly on the deck, insulation or cover board, to which the plies and cap sheet above are bonded. It provides a layer of waterproofing in its own right and a top surface that the next layer can adhere to, while the cap sheet on top provides the colour, ultraviolet resistance and much of the fire resistance.12 Base sheets are used in built-up roofing (BUR), in modified bitumen systems, and in hybrid systems that combine BUR plies with a modified-bitumen cap sheet.1
Because it is the layer actually attached to the building, the base sheet and its method of attachment often decide how the whole membrane resists wind uplift and how it copes with moisture and gases trapped in the deck below.
Place in the membrane
A typical three-ply modified-bitumen roof, from the bottom up, is a base sheet, an interply or second ply, and a granule-surfaced cap sheet. A two-ply system omits the interply. In BUR, the base sheet is followed by several plies of felt laid in hot asphalt and a surfacing of gravel or a cap sheet.12 Multiple plies give redundancy, so a puncture in one layer need not become a leak.2
Unlike the plies above, which are normally fully bonded, the base sheet may be only partly attached, depending on the deck. Base sheets therefore come in different types to suit how they will be fixed.
Types
By reinforcement and binder
- Glass-fibre base sheets. Asphalt-impregnated and asphalt-coated glass-fibre mats, with or without perforations, are covered by ASTM D4601, which describes them as the first ply of a built-up roof. When left unperforated and solidly mopped, the same sheet can serve as a vapour retarder beneath or between layers of insulation.4
- Organic felt and polyester. BUR base sheets can also be made from organic felt or polyester, impregnated with plain asphalt or modified bitumen.12
- SBS- and APP-modified base sheets. Glass or polyester mats coated with styrene-butadiene-styrene (SBS) or atactic polypropylene (APP) modified bitumen. SBS sheets stay flexible in cold weather, while APP sheets need somewhat higher temperatures to heat-weld.12 See SBS-modified bitumen and APP-modified bitumen.
The top surface is finished to suit the next layer: sand, a burn-off film for torch-applied plies, or a release film for self-adhered plies.2
Venting base sheets
A venting base sheet has coarse mineral granules on its underside, which hold the sheet slightly off the substrate and form an open, porous layer through which moisture vapour and gas pressure can spread out sideways instead of lifting the membrane into blisters.3 ASTM D4897 covers asphalt-coated glass-fibre venting base sheets with mineral surfacing on top and coarse granules below. They may be made with or without perforations or embossing, and are meant to be only partly attached, for example by mechanical fasteners or by spot mopping through holes in the sheet.3
Venting base sheets are used chiefly over lightweight insulating concrete and other nailable decks, which can hold a lot of moisture from construction.16 One SBS-modified venting base sheet, 120 mil (3.1 mm) thick, is made for fastening over lightweight insulating concrete on metal decking and over cementitious wood-fibre decks; its embossed granular underside lets vapour move beneath it.6 Venting base sheets are also used in re-cover work, where they separate a new membrane from the old roof and vent gases trapped in it.5 See roof blistering.
Self-adhered base sheets
Self-adhered (peel-and-stick) base sheets have a release liner that is removed as the sheet is unrolled. They avoid hot asphalt and open flame, so they suit occupied buildings that need low odour and low emissions, such as hospitals, and roofs with many penetrations.12 See self-adhered membrane.
Attachment methods
Base sheets are fixed in one of five main ways:12
- Hot-mopped in asphalt from a kettle, the traditional method, which works across a wide range of climates but can be awkward in dense urban areas.2 See hot-mopped built-up roof.
- Heat-welded with torches or hot-air machines that melt the coating, which requires strict fire safety.1 See torch-applied roofing.
- Self-adhered, as above.1
- Cold-applied in adhesive spread with a trowel or squeegee, then rolled in.12 See cold-applied roofing.
- Mechanically fastened, with nails, screws or purpose-made fasteners and plates. This is quick on large roofs and is the normal method on wood, gypsum, wood-fibre and lightweight concrete decks.15
On lightweight insulating concrete, base sheets are fixed with twin-legged expanding fasteners on round metal plates. One range uses plates 2.7 in (69 mm) across, with 1.2 in (30 mm) fasteners for concrete at least 1¼ in (32 mm) thick and 1.7 in (43 mm) fasteners for concrete at least 2 in (51 mm) thick. A site pull test is needed to confirm the deck is suitable, and the fasteners are for multi-ply base sheets only, not single-ply membranes.7 For mechanically fastened sheets, manufacturers call for laps of about 3 in (76 mm) at the sides and 6 in (152 mm) at the ends, with fastening started at the centre of each sheet and worked towards the end laps so the sheet lies flat and under even tension.6
Role in fire and wind ratings
Low-slope roof ratings in North America are given to complete tested assemblies, not single products, so every layer, including the base sheet, has to be compatible with and listed for the assembly.2 The fire resistance of the finished surface comes mainly from the cap sheet, but the base sheet is part of the tested build-up. One venting base sheet, for example, is listed for use in UL Class A fire-rated assemblies.15 See Class A fire rating.
For wind, the base sheet often controls the system's uplift rating, because in a mechanically attached multi-ply roof it is the only layer fixed to the deck. Its fastener type, spacing and lap pattern are therefore set by the system approval. The same venting base sheet is FM Approved in assemblies up to Class 1-345, and fastener approvals for lightweight-concrete base sheets are tied to system approvals rather than to the fastener alone.57 See FM Approved and wind uplift.
Typical specifications
As an example of the products on the North American market:
- A granule-backed nailable venting base sheet to ASTM D4897 Type II is about 39⅜ in (1.0 m) wide, comes in rolls about 40.6 ft (9.9 m) long covering 133 sq ft (12.4 m²) gross, and weighs about 79 lb (35.8 kg) per roll. It is listed for wood, structural wood fibre, poured gypsum and lightweight insulating concrete decks.5
- An SBS-modified venting base sheet, also to ASTM D4897 Type II, is 120 mil (3.1 mm) thick on a glass mat weighing 1.7 lb per 100 sq ft (83 g/m²). It carries at least 12 lb of asphalt per 100 sq ft (586 g/m²) and comes in rolls 1 m × 10 m (39.4 in × 32.8 ft) weighing about 80 lb (36 kg).6
Performance and failure modes
A base sheet that is well fixed and dry when covered rarely fails on its own. Problems usually trace back to installation:
- Blistering, where moisture or air trapped beneath a fully bonded base sheet expands in the sun. Venting base sheets are meant to prevent this on wet decks.35
- Wind damage, where fasteners are too few, too short for the deck, or pull out of weak lightweight concrete or gypsum. Hence the pull-test requirement.7
- Wrinkles and fishmouths, from sheets fastened under uneven tension.6
History and regional practice
Base sheets are a North American convention tied to built-up roofing, where a nailed or mopped first ply has long been laid over wood, gypsum and other decks before the bonded plies (see history of built-up roofing). Today glass-fibre and modified-bitumen sheets dominate, and the trade association ARMA publishes installation guidance for them.2 In Canada, provincial roofing associations keep roof practice manuals, such as the RCABC Roofing Practices Manual, that include manufacturers' data sheets for accepted base sheets.5 In Europe, the equivalent is the underlayer of a two-layer reinforced bitumen membrane system.
Sources
Reviewed 2 November 2026 · 7 sources · 7 cited inline · Editorial policy · Plain-text version · Suggest a correction
- What Is a Base Sheet in Roofing?IKO · iko.com
- What is a roofing base sheet?RoofersCoffeeShop · rooferscoffeeshop.com
- ASTM D4897/D4897M-16(2023) Standard Specification for Asphalt-Coated Glass-Fiber Venting Base Sheet Used in RoofingASTM International · store.astm.org
- ASTM D4601/D4601M-04(2020) Standard Specification for Asphalt-Coated Glass Fiber Base Sheet Used in RoofingASTM International · store.astm.org
- GAFGLAS Stratavent Nailable Venting Base Sheet technical data sheetGAF (via RCABC Roofing Practices Manual) · rpm.rcabc.org
- Base Sheet NB 120 product dataSika USA · usa.sika.com
- RS-7104 Lightweight Concrete Base Sheet FastenersJohns Manville · jm.com