An angled standing seam (German Winkelstehfalz, often called an angle seam or, in North American sheet-metal terms, a type of single-lock standing seam) is a joint between two metal panels in which the taller upstand of one panel is folded down once over the upstand of its neighbour so that the closed seam leans at a right angle, forming an L shape in section. The clips that hold the panels are trapped inside the fold. Because the seam is folded only once and is not compressed into a double lock, it is less watertight than a double standing seam and is reserved for steep roofs and for vertical surfaces, where water runs off quickly.13
The joint is a variant of the standing seam metal roof and is most closely associated with European zinc roofing, where it is a long-established alternative to the double standing seam. It is also made in copper and in coil-coated aluminium.14
How it differs from the double standing seam
Both joints start the same way: each panel (called a bay, tray or pan) is formed with a short upstand on one edge and a taller one on the other, the panels are laid side by side, and clips fixed to the substrate hook over the shorter upstand. The difference is in how the seam is closed.
- In a double standing seam (Doppelstehfalz) the taller upstand is folded over the shorter one, and then the combined seam is folded again, both actions done by a seaming machine or hand tongs, giving a tight four-layer roll that stands upright.2
- In an angled standing seam only one side is closed: the taller upstand is folded over the shorter one, and the combined seam is then bent over to 90 degrees, by machine or by hand.1
- A single-lock standing seam in the North American sense has one sheet extending about 1 in (25 mm) past the other, with the longer upstand folded down over its neighbour.3 It is the simplest form of standing seam and is not recommended in high-wind areas or for large roof or wall areas where strength or watertightness matters.3
The practical consequences are a lower resistance to water driven up the slope or held back by snow, and so a much steeper minimum pitch. One major zinc producer specifies a minimum of 25 degrees for angled-seam roofs, rising to 35 degrees in snowy regions, compared with 3 degrees (about 5.2 percent) for its double standing seam, where seam sealing tape is required between 3 and 7 degrees and wherever ice dams may form.12 In exchange the angled seam puts lower stress on the metal during forming, can be closed quickly by hand, and gives a distinct appearance.1
Dimensions and materials
In titanium-zinc, the angled seam is about 25 mm (1 in) high and about 12 mm (0.5 in) wide when closed.1 Typical specifications are:
- Thickness: 0.7 or 0.8 mm (0.028 or 0.031 in) zinc; 0.8 mm is recommended on mono-pitch roofs with overhangs to reduce wind-induced noise.1
- Bay width: a standard of about 530 mm (21 in) cut from 600 mm (23.6 in) coil, with common widths of 400 to 600 mm (16 to 24 in); on mono-pitch roofs with overhangs, about 430 mm (17 in) is recommended.1
- Tapered bays: from 100 to 730 mm (4 to 29 in) wide, limited to 530 mm on mono-pitch roofs.1
- Length: normally up to 10 m (33 ft) and in special cases up to 16 m (52 ft), but lengths above 10 m restrict the pitch to 30 degrees; longer runs are joined with cross seams.1
The same dimensions apply to that maker's double standing seam, which uses the same coil widths, thicknesses and length limits.2 Panels are formed on roll formers (up to 16 m) or folded on bending brakes (up to 4 m, or 13 ft).1
In aluminium, coil-coated sheet about 0.7 mm (0.028 in) thick is used for angled-seam facades, typically in 500 mm (20 in) bays and lengths up to 12 m (39 ft) on long sliding clips; the system weighs about 2.2 to 2.3 kg/m² (0.45 to 0.47 lb/sq ft) installed and is classed A1, non-combustible, under EN 13501-1.4 In copper, standing seams on flat surfaces are usually at least 1 in (25 mm) high with a 0.5 in (13 mm) lock, and cleats are spaced about 12 in (305 mm) apart and folded into the seam.3
Where it is used
The angled seam is chiefly a facade and steep-roof joint:
- Facades and walls. Laid vertically, horizontally or diagonally, angled seams are widely used for rainscreen cladding, often on the same building as a double-seam roof so that the roof and wall planes read as related but distinct.14 Aluminium facade systems treat it as the main wall option, with a double lock reserved for the roof.4
- Steep roofs, spires and dormer cheeks. On roofs above the minimum pitch, the angled seam gives a crisp, directional look. Curved surfaces can also be covered: in zinc, convex bays down to a 0.6 m (2 ft) radius and concave bays down to 2.5 m (8 ft), with bays laid without pre-curving from about a 12 m (39 ft) radius.1
- Small elements. Fascias, upstands and other small areas are commonly clad with angled seams.1
It is generally not used on shallow roofs, in exposed positions where wind-driven rain can be forced up the seam, or in snow regions below the steeper minimum pitches.13
Installation
The sequence follows normal European folded-metal practice:
- Substrate. The panels must be fully supported on boarding or another continuous substrate.4
- Clips. Fixed clips are placed in a defined zone (usually near the ridge or top of the facade) and sliding clips elsewhere so that the panels can move with temperature; stainless-steel clips are standard.24
- Laying bays. Each bay is hooked over the clips of the previous one and its taller upstand is folded over the shorter one.
- Closing the seam. The combined upstand is bent over to 90 degrees with a seaming machine or hand tools. Because only one fold is made, the work is quick and can be done entirely by hand on small or complex areas.1
- Ends and junctions. Eaves, ridge, verges and openings are formed with the same folded details used for double-seam work, allowing for thermal movement.
Performance, appearance and maintenance
When used at appropriate pitches and on walls, angled-seam cladding has the same long life as the parent metal; zinc is typically offered by producers with multi-decade material warranties.1 The main risks are those of any folded seam pushed beyond its limits: water penetration at pitches that are too shallow, damage from snow and ice sitting against the seam, and noise or fatigue where wide, thin bays are exposed to wind.1 Hand-closed seams can also loosen if the fold is not fully set.
Visually, angled seams look heavier and more sculptural than the slender upright double seam, and the direction in which they lean is a design choice; laid diagonally or horizontally on facades they produce a strong linear pattern.1
History
The angled standing seam has been in use since the early twentieth century, when it developed alongside the double standing seam in central European sheet-metal work.1 Its revival in recent decades has been driven largely by metal facades, where architects use angled seams on walls and double seams on roofs to give one building envelope two related textures.
Sources
Reviewed 2 November 2026 · 4 sources · 4 cited inline · Editorial policy · Plain-text version · Suggest a correction
- Angled standing seamRHEINZINK · rheinzink.com
- Double standing seamRHEINZINK · rheinzink.com
- Additional Loose Lock Seams (Architectural Details: Joints and Seams)Copper Development Association · copper.org