Aluminium Shingles

Also known as aluminum shingles · aluminium shingle roofing · aluminum shingle roof · stamped aluminum shingles · aluminum metal shingles · modular aluminum roofing

Small stamped and painted aluminium roofing units that lock together on their edges and are fixed with concealed nails or clips, used on steep-slope roofs to imitate slate, shingle, shake or tile.

5 min read5 sourcesNorth AmericaGlobal
Cite this entry"Aluminium Shingles." roof.wiki. https://roof.wiki/aluminum-shingles/ (accessed 2026-11-03).
Alloy
3105 (also 3003) aluminium to ASTM B209
Typical thickness
0.019–0.030 in (0.48–0.76 mm) base metal
Installed weight
About 0.41–0.71 psf (2.0–3.5 kg/m²)
Finish
PVDF (fluorocarbon) paint, about 0.8–1.0 mil (20–25 µm) over primer
Minimum slope
Usually 3:12 (14°); up to 5:12 with mechanically fastened underlayment
Fire classification
Class A to C depending on underlayment system
Code evaluation
ICC-ES reports under AC166; IBC 1507.5 / IRC R905.4

Interlocking metal shingles

Layers from the surface down.

  1. Deck
  2. Underlayment
  3. Starter strip and metal shingle panels
  • Pressed metal panels that hook into the panels beside and below them.
  • Each panel is embossed to look like several slates or shakes; fasteners are hidden by clips or by the course above.
  • The first course locks into a starter strip at the eave.
  • Laid from the eave up; each course laps down over the one below.

Model shows typical proportions, not a specification. Follow the manufacturer's instructions and local code.

Quick answers

What is Aluminium Shingles?
Small stamped and painted aluminium roofing units that lock together on their edges and are fixed with concealed nails or clips, used on steep-slope roofs to imitate slate, shingle, shake or tile.
What is the minimum roof pitch for Aluminium Shingles?
Usually 3:12 (14°); up to 5:12 with mechanically fastened underlayment
What fire rating does Aluminium Shingles have?
Class A to C depending on underlayment system

Aluminium shingles are small roofing units pressed from painted aluminium coil, typically between about 10 and 60 in (250 mm and 1.5 m) long. Each unit hooks or locks into its neighbours and is fixed to the roof deck with nails or clips hidden beneath the next course.12 They are a steep-slope residential roof covering, part of the wider metal shingle family, and are made to look like other materials. Common designs reproduce slate, sawn cedar shingles, split shakes and clay or concrete tile, and some imitate architectural asphalt shingles.134

Within aluminium roofing, shingles differ from standing seam and corrugated sheet in scale and appearance. A standing seam roof is made of long, flat pans, while a shingle roof is built from many small units laid in overlapping courses.4 Within metal shingles, aluminium is set apart from steel and stone-coated steel by its natural corrosion resistance and very low weight. In the evaluated products cited here, an aluminium shingle roof weighs roughly half as much as the same profile in galvanized steel.2

Roof deck + underlayment seamer Panel legs stand up at each side— no fasteners through theweathering surface. Clip holds the panel, lets itmove with temperature.Double lock: legs folded 180°twice into a watertight seam.
How a standing seam is formed

Material and coatings

North American aluminium shingles are mostly made from alloy 3105, and sometimes 3003, conforming to ASTM B209, in strain-hardened tempers such as H24, H26 or H27.12 Typical base-metal thicknesses in code evaluation reports are:

  • 0.019 in (0.48 mm) for many shingle and shake units;12
  • 0.024 in (0.61 mm) for one long-format shingle;1
  • about 0.028 to 0.030 in (0.70 to 0.76 mm) for larger tile and shake panels.12

The exposed face is factory-painted on a coil line with a fluoropolymer (PVDF) finish. One report specifies about 0.2 mil (5 µm) of corrosion-inhibiting primer under 0.8 mil (20 µm) of PVDF, with a wash coat on the back.1 Another requires at least 1.0 mil (25 µm) of fluorocarbon paint on the top surface and 0.5 mil (13 µm) on the underside.2

How the units fit together

Designs vary, but all share three features:

  1. A locking edge. The bottom edge of each unit hooks into a lip or channel on the course below, and the side edges overlap or lock, so the roof forms a continuous mechanical skin.12
  2. A concealed fastening strip. The top edge carries a nailing hem or slots, or is held by separate clips, and is covered by the next course.12
  3. A starter and trim system. Eave starter strips, gable and rake trims, and ridge and hip caps make up the edges. In one system, the first course of shingles hooks into the lip of the eave starter.2

Dimensions and weight

Unit sizes in two ICC-ES reports range from about 10.4 × 18.2 in (263 × 462 mm) for a small slate-style shingle to 12.8 × 60.6 in (325 × 1,539 mm) for a long multi-tab shingle, and 44 in (1,121 mm) wide for multi-course tile panels.12 Installed weights are:

head lap Rafter + battens Slates hang in courses from the eave up.Each is nailed (or hooked) to a batten andreaches two courses up, so there are alwaysat least two thicknesses over the roof.
How slates are fixed
Unit type Installed weight
Small shingle or diamond 0.41–0.44 psf (2.0–2.1 kg/m²)
Long shingle 0.42 psf (2.1 kg/m²)
Shake panel 0.47–0.58 psf (2.3–2.8 kg/m²)
Tile panel 0.59–0.71 psf (2.9–3.5 kg/m²)

Values are from ICC-ES reports ESR-1360 and ESR-1790.12 For comparison, standard reference tables give about 2 psf (10 kg/m²) for asphalt shingles, 3 psf (15 kg/m²) for wood shingles, 7 to 10 psf (34 to 49 kg/m²) for 3/16 to 1/4 in slate, 12 psf (59 kg/m²) for concrete tile and 19 psf (93 kg/m²) for Spanish clay tile.5

Code approval, fire and wind

In the United States, aluminium shingles are accepted under the metal roof shingle provisions of the International Building Code (Section 1507.5) and International Residential Code (Section R905.4). Most are documented in ICC-ES evaluation reports issued under acceptance criteria AC166.2 The reports set out the conditions that apply:

  • Minimum slope. One manufacturer's products are approved down to 3:12 (25 per cent, about 14°).1 Another's needs 3:12 with a self-adhered underlayment, but 4:12 or 5:12 (about 18 to 23°) with a mechanically fastened underlayment, depending on the profile.2
  • Fire classification. This depends on the underlayment. In one report, a single layer of Type II felt gives Class C, one layer of ASTM D3909 fibreglass cap sheet gives Class B, and two layers give Class A.1 In another, Class A or B needs a specified fire-resistant underlayment, and the roof is non-classified over a self-adhered underlayment.2
  • Wind uplift. Allowable design pressures depend on the fastening pattern. One small shingle ranges from about 29.9 psf (1.4 kPa) with one nail per unit to 177.5 psf (8.5 kPa) with added clips and up to seven fasteners per unit.2 Other products are rated at about 56 to 65 psf (2.7 to 3.1 kPa).1

Installation

Aluminium shingles are installed over solid sheathing, usually plywood at least 15/32 in (12 mm) thick, with an underlayment and ice barrier as the code requires.12 Fasteners must be compatible with aluminium, such as aluminium nails or stainless-steel screws. They are driven through clips or the nailing hem, with penetrations of 1/2 to 1 in (13 to 25 mm) into or through the deck, at spacings as close as 6 to 8 in (150 to 200 mm) for clip-fixed units.12 Valleys are built on metal valley flashing. Units are cut and folded at the valley, and in one report nails must stay at least 9 in (229 mm) from the valley flashing.1

Because they are light, aluminium shingles can often be installed over one layer of existing asphalt shingles. Both reports allow this where the slope and code allow, provided old ridge caps and flashings are removed. One also permits installation over wood shingles or medium shakes if the old surface is first covered with an approved separation board.12

Performance and maintenance

Aluminium does not rust or rot and needs no sealing or staining, and with the specified underlayment these roofs can reach a Class A fire classification.412 Maintenance is mostly limited to clearing debris from valleys and gutters and checking flashings and sealants at penetrations.

Failure modes include:

  • denting from very large hail or foot traffic on thin units;
  • fastener problems if steel nails are used, or galvanic corrosion where the aluminium touches copper or bare steel;
  • leaks at poorly formed valleys, chimneys and wall junctions;
  • fire classification lost by installing the wrong underlayment.12

Use

Aluminium shingles are used mainly on houses, where light weight, corrosion resistance and the look of traditional materials are valued. Their low weight makes them a common choice for re-roofing older houses whose framing was designed for light roofs.15

Sources

Reviewed 2 November 2026 · 5 sources · 5 cited inline · Editorial policy · Plain-text version · Suggest a correction

  1. ESR-1360: Metal Roof Panels and ShinglesICC Evaluation Service · icc-es.org
  2. ESR-1790: Metal Roof Panels and ShinglesICC Evaluation Service · icc-es.org
  3. What Are Aluminum Shingles?interlockroofing.com · interlockroofing.com
  4. Types of Aluminum Roofinginterlockroofing.com · interlockroofing.com
  5. Weights of Building Materials (GE-1)Boise Cascade · cdn.mediavalet.com

From the community

Know this topic first-hand? Share a photo you took, a correction with a source, or local knowledge. Every contribution is reviewed before it appears.

Contribute to Aluminium Shingles

Loading…