Aluminium Shake Roofing

Also known as aluminum shake roofing · aluminum shakes · aluminium shakes · metal shake roofing · aluminum cedar shake · aluminum cedar shingle · faux cedar shake metal roof

Aluminium roofing shingles or panels pressed and embossed to imitate split cedar shakes or sawn cedar shingles, used as a light, non-rotting alternative to wood on steep-slope roofs.

5 min read6 sourcesNorth America
Cite this entry"Aluminium Shake Roofing." roof.wiki. https://roof.wiki/aluminum-shake-roofing/ (accessed 2026-11-03).
Material
3105-series aluminium, about 0.019–0.028 in (0.48–0.70 mm), PVDF-painted
Typical panel
About 14 × 48–50 in (350 × 1,250 mm), several shakes per panel
Installed weight
About 0.47–0.58 psf (2.3–2.8 kg/m²)
Wood shingle weight for comparison
About 3 psf (15 kg/m²)
Fire classification
Class A, B or C by assembly, depending on underlayment
Minimum slope
3:12 (14°) to 4:12 (18°) depending on product and underlayment
Wood shakes it imitates
18 and 24 in (457 and 610 mm) split or sawn cedar

Quick answers

What is Aluminium Shake Roofing?
Aluminium roofing shingles or panels pressed and embossed to imitate split cedar shakes or sawn cedar shingles, used as a light, non-rotting alternative to wood on steep-slope roofs.
What fire rating does Aluminium Shake Roofing have?
Class A, B or C by assembly, depending on underlayment
What is the minimum roof pitch for Aluminium Shake Roofing?
3:12 (14°) to 4:12 (18°) depending on product and underlayment

Aluminium shake roofing is a steep-slope roof covering made of painted aluminium units stamped to look like a wood roof. Some imitate rough, deeply textured split cedar shakes; others imitate the thinner, more regular look of sawn cedar shingles. The units are usually wide panels that each represent several shakes, with uneven butt lines and woodgrain embossing, and they lock into one another and are fixed with concealed nails or clips.126 They belong to two parent families at once: they are a form of aluminium metal shingle, and they are one of several manufactured substitutes for wood shakes, alongside stone-coated steel and synthetic polymer shakes.

The products are designed to give the look of a cedar roof without the maintenance, decay and combustibility of wood. They are used mostly on houses and cottages in North America, often to replace an existing wood roof.

  • Compared with wood shakes. Cedar shakes are split or sawn pieces 18 or 24 in (457 or 610 mm) long and at least 4 in (102 mm) wide, about 1/2 to 3/4 in (13 to 19 mm) thick at the butt, laid with exposures of up to about 7-1/2 in (191 mm) or 10 in (254 mm).3 Aluminium shake panels reproduce this rhythm with pressed relief rather than real thickness. They are only a few hundredths of an inch thick, but the embossing gives a shadow line.12
  • Compared with other aluminium shingles. Slate-pattern units are usually small, flat and regular. Shake-pattern units are larger multi-shake panels with deeper relief, irregular tab widths and staggered butts.12
  • Compared with stone-coated steel shakes. Stone-coated products use a heavier steel base with bonded granules for texture. Aluminium shakes rely on paint and embossing and weigh less.

Materials and dimensions

Evaluated aluminium shake products use alloy 3105 to ASTM B209, about 0.019 in (0.48 mm) thick for shake units or 0.0276 in (0.70 mm) for larger shake panels.12 The exposed face carries a fluoropolymer (PVDF) finish over primer, in wood-tone colours.12

Two examples from ICC-ES reports show the typical format:

  • A shake panel about 14.6 × 48.4 in (371 × 1,229 mm), weighing 1.88 lb (0.85 kg) per piece and about 0.47 psf (2.3 kg/m²) installed, fixed through its nailing hem at 12 in (305 mm) centres.1
  • A shake panel 13.5 × 50 in (343 × 1,270 mm) overall, with a 12.5 × 47 in (318 × 1,194 mm) exposure and an installed weight of about 0.58 psf (2.8 kg/m²). It is fixed with three or four equally spaced fasteners per panel, partly through clips, and side laps are 3 in (76 mm).2

For comparison, reference tables give about 3 psf (15 kg/m²) for wood shingles and 2 psf (10 kg/m²) for asphalt shingles.5 An aluminium shake roof therefore weighs a fraction of the wood roof it replaces, and it does not take on water the way wood does.

Eave · starter course first Courses go on fromthe eave up. Each onecovers the nails below;joints are offset.
How shingles are laid

Fire performance

Fire resistance is the main technical difference from wood:

  • Untreated wood shakes and shingles are generally treated as unrated, the most vulnerable roof class in wildfire areas.4 Class A, B and C wood roofs need pressure-impregnated fire-retardant shakes. Class A, the highest, is reached only as a component system with additional layers.3
  • Aluminium does not burn, but its low melting point means it is not automatically accepted as a Class A covering the way many other metal roofs are. It has to be tested and installed with an extra fire-resistant layer under it, giving a rating "by assembly".4

The ICC-ES reports show how the class depends on the layers beneath. For one product line, a single layer of Type II felt gives Class C, one fibreglass cap sheet gives Class B, and two cap sheets give Class A.1 For another, Class A or B depends on a named fire-resistant underlayment, and the roof becomes non-classified over a self-adhered underlayment.2

Wildfire zones

In wildland-urban interface areas, a roof's class rating is only part of its performance. Embers can lodge in gaps at ridges and eaves, so those openings should be closed ("bird stopping"). Debris must be kept off the roof and out of the gutters, and on Class A roofs the walls, windows and roof-wall intersections often govern how vulnerable a house is.4 Codes may also need specific listings. One aluminium shake report states that it has not been evaluated under California's Chapter 7A or the International Wildland-Urban Interface Code, so local acceptance must be confirmed separately.2

Installation

Aluminium shake panels go over solid sheathing, at least 15/32 in (12 mm) plywood in the reports cited, with the code-required underlayment and ice barrier.12 The general sequence is:

  1. Install the eave starter, valley flashings, and gable or rake trims.
  2. Lay the first course from the eave. In one system the panels start at the eave and overlap 3 in (76 mm) on the right side.2
  3. Fix each panel through its hem or clips, with aluminium or other compatible nails that penetrate at least 1/2 to 1 in (13 to 25 mm) into or through the deck.12
  4. Cut and form panels at valleys, and keep fasteners clear of the valley flashing.12
  5. Finish with ridge and hip caps that match the shake texture.

Minimum slopes are 3:12 (about 14°) for one manufacturer's products, and 3:12 with a self-adhered underlayment or 4:12 (about 18°) with a mechanically fastened one for another.12 Allowable wind uplift pressures for evaluated shake systems range from about 37.5 to 115 psf (1.8 to 5.5 kPa), depending on how the panels are fastened.2

Re-roofing over old roofs

The panels are light enough to go over many existing roofs. One report permits installation over existing asphalt shingles, wood shingles or medium wood shakes on solid sheathing. Over wood, the old surface must first be covered with an approved separation material such as gypsum, mineral-fibre or glass-fibre board. Deteriorated roofing must be removed, ridge and hip caps stripped, and overhanging material at the eaves cut flush.1 Another report allows installation over existing asphalt shingles, with all old flashings, vents and valleys replaced.2

Durability and maintenance

Aluminium shakes do not rot, split, cup or grow moss in the way wood does, and they need no staining or preservative treatment. Unlike cedar, they do not weather to silver-grey; the colour is set by the factory PVDF finish.16 Maintenance consists mainly of clearing leaves and needles from valleys and gutters, which matters for both drainage and wildfire resistance.4 They can be damaged by dents from large hail or careless foot traffic, by fasteners that are incompatible with aluminium, and by poorly made flashings at chimneys and walls.

Sources

Reviewed 2 November 2026 · 6 sources · 6 cited inline · Editorial policy · Plain-text version · Suggest a correction

  1. ESR-1360: Metal Roof Panels and ShinglesICC Evaluation Service · icc-es.org
  2. ESR-1790: Metal Roof Panels and ShinglesICC Evaluation Service · icc-es.org
  3. Certi-Split Handsplit & Resawn ShakesCedar Shake and Shingle Bureau · cedarbureau.org
  4. Fire-Resistant RoofsFire Safe Marin · firesafemarin.org
  5. Weights of Building Materials (GE-1)Boise Cascade · cdn.mediavalet.com
  6. Types of Aluminum Roofinginterlockroofing.com · interlockroofing.com

From the community

Know this topic first-hand? Share a photo you took, a correction with a source, or local knowledge. Every contribution is reviewed before it appears.

Contribute to Aluminium Shake Roofing