EN 14437

Also known as BS EN 14437 · NF EN 14437 · tile uplift test

EN 14437 is the European test method for measuring the wind uplift resistance of installed clay and concrete roof tiles on a test roof.

1 min read2 sourcesEurope
Cite this entry"EN 14437." roof.wiki. https://roof.wiki/en-14437/ (accessed 2026-11-02).
Publisher
CEN
Current edition
EN 14437:2022 (replaced 2004 edition)
Applies to
Clay tiles (EN 1304) and concrete tiles (EN 490)
Not applicable
Fewer than every third tile fixed; under-and-over tiles

EN 14437, Determination of the uplift resistance of installed clay or concrete tiles for roofing – Roof system test method, is a European Standard published by CEN. The current edition is EN 14437:2022, which replaced EN 14437:2004. It is adopted nationally as, for example, BS EN 14437 in the UK, NF EN 14437 in France and SS-EN 14437 in Sweden.

Scope

The method establishes how much uplift force an installed tile system can resist. It applies to clay tiles to EN 1304 and concrete tiles to EN 490, whether they are laid without fixings or held by mechanical fixings such as clips, hooks, screws or nails.

Pans (concave) are laid first and carry the water.Covers (convex) sit over the joints between them.Each course overlaps the one below up the slope.
How pan and cover tiles shed water

It does not apply:

  • where fewer than one tile in three is fixed
  • to under-and-over tile systems (such as some Roman or Spanish profiles)

A note in the standard says the method can be extended to other discontinuous roof elements, including natural and fibre-cement slates and stone, and, with adaptation, to solar panels fixed into tiled roofs.

head lap Rafter + battens Slates hang in courses from the eave up.Each is nailed (or hooked) to a batten andreaches two courses up, so there are alwaysat least two thicknesses over the roof.
How slates are fixed

How it is used

Results from EN 14437 feed into national calculation methods. In the UK, BS 5534 uses tile uplift resistance data together with wind loads from EN 1991-1-4 and its UK National Annex to determine which tiles must be fixed and with what fixings. Tile and fixing manufacturers use the results to produce fixing tables for different wind zones, roof pitches and building heights.

Why it matters

Single-lap tiles that lock into their neighbours rely partly on their own weight and partly on those side and head locks to resist wind. Testing a whole installed system captures how neighbouring tiles help hold each other down, which a test on a single tile would miss. This is why European practice increasingly calls for fixing schedules based on system tests rather than simple rules of thumb.

Sources

  1. EN 14437:2022Genorma · genorma.com
  2. SS-EN 14437:2022Swedish Institute for Standards · sis.se