Quick answers
- What is 5V Crimp Panel?
- A through-fastened steel roofing panel, usually 24 in (610 mm) wide, with five low V-shaped crimps, laid over solid decking and long associated with houses in Florida and the US Southeast.
- What is the minimum roof pitch for 5V Crimp Panel?
- 3:12 typical (1/2:12 with sealant per IBC)
A 5V crimp panel (also written 5-V crimp or simply 5V) is an exposed-fastener metal roofing sheet with five small V-shaped ribs, or crimps, running its length: one at each edge, where neighbouring panels overlap, and three across the flat field between them. The crimps are low, typically about 1/2 in (13 mm), and the panel covers about 24 in (610 mm) of roof.12 Because the shallow ribs give the panel little stiffness of its own, 5V is laid over a solid wood deck and underlayment and screwed down through the crimps, rather than spanning between purlins like deeper commercial profiles.12
The 5V panel is one of the main profiles in the family of through-fastened metal panels. Compared with its siblings it sits between corrugated sheet and the trapezoidal R-panel. The common 7/8 in (22 mm) corrugated profile has rounded ribs at about 2.67 in (68 mm) centres, and the R-panel has 1 1/4 in (32 mm) trapezoidal ribs at 12 in (305 mm) centres across a 36 in (914 mm) sheet, deep enough to span purlins.5 5V has ribs at roughly 12 in (305 mm) centres like an R-panel, but much shallower and V-shaped, which gives it a flatter, more residential look that some people compare with standing seam.1
History
Sheet-metal roofing spread widely in the United States after production expanded in the mid-nineteenth century, and the range of metal roof types grew in the early twentieth century.4 Corrugated and paneled metal such as 5V crimp was popularised in the twentieth century, and Florida preservation guidance describes 5V crimp panels as becoming popular in the mid to late twentieth century.4 The profile became a common roof on frame houses, farm buildings and coastal cottages across Florida and the Gulf and South Atlantic states, where metal sheds heavy rain, resists wind when properly fastened and reflects sun.
It is now used on houses, agricultural buildings and light commercial projects.1 Because it is so familiar locally, 5V is often chosen to replace earlier roofs on older houses, though preservation authorities do not always accept it as a match: in one Florida historic district, staff reviewing a 1920s Frame Vernacular house recommended against replacing its metal shingle roof with 5V crimp because the change would alter the building's historic design under the Secretary of the Interior's Standards.6
Dimensions and materials
Typical specifications from US manufacturers are:
- Coverage: 24 in (610 mm); some regional and approved products range from about 20.5 to 24 in (521 to 610 mm).123
- Crimp height: 1/2 in (13 mm), ribs at 12 in (305 mm) centres.12
- Gauge: 29 or 26 gauge for general use; 24 gauge is widely used in Florida, where some high-wind approvals call for 24 gauge minimum steel with a 58 ksi (400 MPa) minimum yield strength.123
- Length: cut to length, typically one piece from eave to ridge; one manufacturer recommends a maximum of 45 ft (13.7 m) and minimum of 5 ft (1.5 m).2
- Coatings: aluminium-zinc (Galvalume) to ASTM A792, typically AZ55 bare or AZ50 under paint, or galvanised G90 to ASTM A653, with polyester, silicone-modified polyester or PVDF paint systems.21
Most 5V is roll-formed steel, though aluminium versions are made for coastal sites.
Installation
A standard installation over wood decking follows these steps:
- Deck. Solid plywood or plank decking. One Florida high-wind approval requires at least 19/32 in (15 mm) plywood or plank decking for new construction and 15/32 in (12 mm) for re-roofing, fixed with at least 8d ring-shank nails at 6 in (152 mm) centres.3
- Underlayment. At least No. 30 felt or an approved synthetic; in the same approval, ASTM D226 Type II felt with 4 in (102 mm) side laps and 6 in (152 mm) end laps, nailed with tin caps.23
- Panels. Laid from the eave upward and across the roof, each panel's edge crimp overlapping the previous one.
- Fasteners. Corrosion-resistant #10 hex-washer-head wood screws with sealing washers, driven through the overlapping crimps parallel to the slope; fastening at the centre crimp may be optional depending on the approval.32 In the approval cited, screws are spaced 16 in (406 mm) apart in the field and 8 in (203 mm) at perimeters and corners, achieving design uplift pressures of 82.25 psf (3.94 kPa) in the field and 176 psf (8.43 kPa) at perimeters and corners.3 Screws should penetrate at least 1/2 in (13 mm) beyond the face of the support or, for sheathing, through it; overdriving distorts the panel.23
- Sealing. Side-lap sealant is added where internal pressures are high, such as partially enclosed buildings.2
- Trim. Ridge, hip, eave, rake and valley trims are fixed with stitch screws, with closures under the ridge.
Minimum slope and ratings
Manufacturers generally specify a minimum slope of 3:12 (25 percent) for 5V, though the International Building Code permits lapped, non-soldered metal panels with side-lap sealant down to 1/2:12.12 Published ratings for one 26-gauge product include UL 580 Class 90 uplift, UL 2218 Class 4 impact, Class A fire under UL 790 as permitted by the building code, Texas windstorm evaluation, Florida product approval and a Miami-Dade notice of acceptance.2 Approvals for the Florida High-Velocity Hurricane Zone are based on Florida test protocols TAS 100, TAS 110 and TAS 125.3
Comparison with standing seam
5V is often chosen as a lower-cost alternative to standing seam for houses. The differences are:
- Fastening: 5V uses exposed screws through the panel; standing seam uses concealed clips.
- Thermal movement: through-fastened 5V cannot slide on its fixings, so long panels in hot climates load the screws and can elongate holes; standing-seam clips allow movement.
- Maintenance: the rubber washers on exposed screws age and fastener back-out is the main long-term maintenance task.
- Appearance: 5V's low, evenly spaced crimps read as a flat, ribbed surface; standing seam has taller, more pronounced seams.
- Cost: 5V uses simpler roll-forming and faster installation.
Performance and failure modes
With a good coating and fasteners, 5V roofs give long service in hot, wet climates. Common problems are fastener back-out and washer failure, leaks at side laps that were not sealed on low slopes, red rust at cut edges and scratches near the coast, and oil canning or panel distortion from overdriven screws.2 Florida historic-preservation guidance recommends repainting worn finishes, refastening loose panels and using a single compatible metal for fasteners, flashings and gutters to avoid galvanic corrosion.4
Sources
Reviewed 2 November 2026 · 6 sources · 6 cited inline · Editorial policy · Plain-text version · Suggest a correction
- 5V CrimpMBCI · mbci.com
- 5V-Crimp Component Technical Reference 2024Metal Sales Manufacturing · metalsales.us.com
- FL24423: 5-V-Crimp 24 ga. (min) Steel Panel over Wood DeckFlorida Building Commission · floridabuilding.org
- Historic preservation roofing guidelinesCity of Fort Lauderdale · fortlauderdale.gov
- Most Commonly Used Metal Roofing ProfilesSwenson Shear / Southern Tool · southern-tool.com
- COA Staff Report, 606 S 8th Street, roofHistoric Preservation Board, Florida · public.destinyhosted.com