A root barrier is a membrane or layer in a green roof that stops plant roots and rhizomes from penetrating, damaging or growing into the roof waterproofing. It may be a separate sheet laid over the waterproofing, typically of plastic such as polyethylene or another polyolefin, or the waterproofing membrane itself may be formulated and tested to be root-resistant, in which case the two functions are combined in one layer. The German FLL green roof guidelines state the requirement simply: the root barrier must permanently prevent damage to the waterproofing from penetrating roots.6
Root barriers are an essential component of every green roof type, from thin sedum extensive green roofs to deep intensive green roofs and rooftop farms. Some building codes make them mandatory: Toronto's green roof construction standard requires a root barrier in all vegetated roof systems.7 Root barriers used on roofs are distinct from the vertical root barriers installed in the ground to stop tree roots damaging foundations, pavements and drains.
Why roofs need root protection
Roots seek out water and nutrients and exploit any weakness. On a green roof they grow down through the substrate and drainage layers until they meet the waterproofing, where they can enter seams, laps, fixings and surface defects. Woody plants, whether planted or self-sown, can force open joints as their roots thicken, and grasses with running rhizomes, such as couch grass, can drive sharp rhizome tips into or through membranes. Organic waterproofing materials can also be attacked chemically or biologically. Tests show that weak points are often at seams rather than in the main sheet: in one two-year test of a heat-welded membrane, roots did not penetrate the sheet or the welded seams, but they grew between a sealant bead and the membrane and through the sealant, which the researchers concluded should not be relied on for waterproofing in a green roof.5 A bitumen membrane manufacturer likewise reports roots passing through the overlaps of film- or foil-reinforced sheets where the protective layer was not continuous at laps.3
Types
Separate root barrier sheets. Plastic sheets, commonly polyethylene or other polyolefins, laid loose over the waterproofing with welded or wide taped laps, and turned up at edges and penetrations. Green roof suppliers specify such barriers wherever the underlying waterproofing is not itself root-resistant.8
Root-resistant waterproofing membranes. Many single-ply and bitumen membranes are manufactured and certified as root-resistant so that no separate barrier is needed. Bitumen is not inherently resistant, so manufacturers add a root inhibitor to the bitumen compound or incorporate a continuous protective layer. One polymer-bitumen membrane gains its resistance from a phenoxy fatty acid ester added to the compound, on a spunbond polyester reinforcement chosen to avoid the lap gaps found in film- or foil-reinforced sheets; it is 4 mm thick.3 Another is an elastomeric bitumen torch-on capping sheet 5.2 mm (0.20 in) thick on a 250 g/m² polyester reinforcement, declared as having passed the FLL root-resistance test.4 Synthetic membranes such as PVC, TPO, EPDM and flexible polyolefins, and some liquid-applied membranes, are also offered in versions tested to FLL or EN 13948, with welded or bonded seams included in the test.15
Combined protection and barrier layers. Some green roof systems use composite sheets that combine a root barrier with a protection fleece.
Testing standards
Because root resistance cannot be judged from material type alone, it is proved by long-term planting tests on the actual product, including its seams.
- FLL procedure (Germany). The FLL method is a two-year test in which troughs lined with the membrane are planted with firethorn (Pyracantha coccinea) and couch grass (Agropyron repens, also known as Elymus repens), with interim and final assessment of penetration; products that pass are certified root-resistant, and, where couch grass is used, rhizome-resistant.1 The procedure is published as an appendix to the FLL green roof guidelines.6 Passing the FLL test also implies passing EN 13948.1
- EN 13948 (Europe). The European standard method for determining resistance to root penetration of flexible bitumen, plastic and rubber sheets for roof waterproofing uses troughs planted only with firethorn.1
- ANSI/SPRI VR-1 (North America). Procedure for Investigating Resistance to Root or Rhizome Penetration on Vegetative Roofs, approved on 11 June 2018, is based on the FLL method and intended as an equivalent for North American test sites.2 It runs for 24 months of active growth, and never less than 21 months after plants reach 60 per cent root or rhizome coverage, using Pyracantha coccinea 'Orange Charmer' and Elymus repens.2 Each barrier is tested in six containers at least 800 × 800 × 250 mm (32 × 32 × 10 in) with transparent bases, plus three unlined control containers per run; the liners include four vertical corner seams, two seams along the base corners and a T-seam in the middle.2 A barrier fails if roots or rhizomes pass through the sheet or its seams and are visible at the bottom of the container.2
- DIN CEN/TS 14416. A separate lupin-based test is used for geosynthetic barriers.1
Testing institutes in Germany and the Penn State Center for Green Roof Research in the United States are among those that carry out these tests.15
Limits of certification
Tests cover normal root and rhizome growth. They do not cover aggressively spreading plants such as bamboo and Chinese reed (Miscanthus), which need extra protection and management; VR-1 states explicitly that its results do not apply to such plants, and the FLL guidelines note that bamboo species may need additional protective membranes and special maintenance.26 Certification applies only to the product and seam method tested, so site seams must be made in the same way.25 The FLL guidelines also prefer root-resistant waterproofing on roofs pitched above 10°.6
Installation
- Check compatibility. Confirm that the barrier is compatible with the waterproofing and with fertilisers and humic acids in the substrate.3
- Lay and seam. Lay sheets over the entire green roof area, with laps welded, bonded or overlapped as the test certificate specifies. Sealant should not be relied on as the only barrier at seams.5
- Turn up at edges. Take the barrier up walls, upstands, outlets and penetrations to above the finished substrate level.
- Protect. Cover the barrier with a protection fleece or mat before placing drainage, substrate and plants. FLL guidance calls for protective geotextiles at least 2 mm thick with a mass of at least 300 g/m² and laps of at least 10 cm (4 in).6
- Test. Leak-test the waterproofing before the green roof is laid; Toronto requires a successful leak test and a signed report before installation.7
Maintenance and failure
Root barriers are inaccessible once covered, so prevention matters: woody seedlings and invasive grasses should be removed during routine maintenance before their roots reach the membrane, and drains and vegetation-free margins should be kept clear. Failures usually show as leaks and are traced to seams, penetrations and edges, or to woody plants and rhizome-forming grasses that the barrier was not designed to stop.25
Sources
Reviewed 2 November 2026 · 8 sources · 8 cited inline · Editorial policy · Plain-text version · Suggest a correction
- Root resistanceSKZ – German Plastics Center · skz.de
- Defend Antiroot technical documentIndex / Sika South Africa · zaf.sika.com
- BauderPLANT E Roofing Membrane Technical Data SheetBauder · bauder.co.uk
- Waterproofing test report summary: Hyload Inc.Penn State Center for Green Roof Research · plantscience.psu.edu
- Green Roof Guidelines (FLL, 2018 edition)FLL / BCIT Centre for Architectural Ecology · commons.bcit.ca
- Toronto Green Roof Construction StandardCity of Toronto · ero.ontario.ca
- Intensive Green Roofs (planning guide, 05/2023)ZinCo · zinco-greenroof.com