Glass Roof

Also known as glazed roof · overhead glazing · sloped glazing · patent glazing · atrium roof · glass canopy

A roof wholly or largely made of glass panes carried on metal or timber framing, such as patent glazing, atrium and courtyard roofs and station roofs, designed for daylight, loads, drainage and safe access.

5 min read6 sourcesGlobal
Cite this entry"Glass Roof." roof.wiki. https://roof.wiki/glass-roof/ (accessed 2026-11-03).
Sloped glazing defined
Glazing more than 15° from vertical (IBC 2405)
Permitted glass (IBC)
Laminated (≥30 mil interlayer), wired, heat-strengthened, fully tempered, approved plastics
Screens
Required under tempered/heat-strengthened glass; not under laminated
Patent glazing minimum pitch
About 15°
UK code
BS 5516-1 (sloping and vertical patent glazing)
Glass dead load
About 2.5 kg/m² per mm of thickness
Landmark example
British Museum Great Court roof, 2000: 3,312 panes, 6,100 m²

Patent glazing

Layers from the surface down.

  1. Purlins
  2. Glazing bars and caps
  3. Gaskets
  4. Glass
  • Glazing bars run down the slope, typically about 600 mm apart.
  • The glass rests on gaskets on the bar shoulders; a cap clamps it from above.
  • The glass overhangs the eave into a gutter, held by an end-stop clip.

Model shows typical proportions, not a specification. Follow the manufacturer's instructions and local code.

A glass roof is a roof in which glass, rather than an opaque covering, forms most of the weather surface. It is carried on glazing bars, framing members or a structural grid of steel, aluminium or timber. Glass roofs range from small rooflights and lean-to glazing to large atrium, courtyard, arcade and railway-station roofs.12 They differ from individual skylights, which are discrete units set in an opaque roof, and from plastic-glazed roofs such as polycarbonate, GRP and ETFE foil.

History

Glass was used in roofs once it could be made cheaply in sheets of adequate size. Rooflights appeared in Britain and most of Europe in the mid-18th century. The simplest were single panes set into tiled roofs, used mainly on secondary and farm buildings because they could not be opened, cleaned or repaired easily. Large panes running top to bottom were preferred, since horizontal glazing bars or lead cames between small panes tended to leak.1 In Britain an excise duty on glass, charged by weight from the mid-18th century, favoured small, thin panes; its removal in 1845, together with better manufacturing, made large sheets of good-quality glass relatively cheap by the late 19th century.1

The Victorians developed patent glazing and used it confidently on railway stations and museums, which used vast areas of overhead glass. Examples include the Leeds Corn Exchange, the Oxford University Museum, and the Crystal Palace of 1851, which used overhead glazing on an unprecedented scale.1 See Crystal Palace and Joseph Paxton. Mass-produced cast-iron rooflights followed in the mid-19th century, and survive most often over the stairwells of late Victorian and Edwardian terraced houses.1

Early patent-glazing bars were steel sections covered with lead. Aluminium, developed during the Second World War, became the main bar material in the 1950s and 1960s because of its lower weight and cost.2 Large modern glass roofs on steel grids include the roof of the Queen Elizabeth II Great Court at the British Museum in London, opened on 6 December 2000.5

Systems

Patent glazing

Patent glazing is a non-load-bearing dry glazing system in which glass panels are supported along two edges by glazing bars. The bars carry the glass's own weight plus wind and snow loads but do not contribute to the stability of the building. Its name comes from the many patents taken out for versions of it in the 19th and 20th centuries.2 Modern bars are aluminium T or box sections fixed back to the main structure. They are available up to about 7–8 m (23–26 ft) long, and generally need intermediate support beyond about 3–6 m (10–20 ft), depending on size and loads.2 Internal channels in the bars collect any rain that passes the outer seal, together with condensation, and drain them to the outside.2 Because it needs only two-edge support, patent glazing is more economical than four-edge curtain-wall systems for sloping glass.2 In the UK, BS 5516-1 covers the design and installation of sloping and vertical patent glazing.2

Framed and structural glass roofs

Larger roofs use four-edge-supported glazing units in aluminium or steel framing, or glass panels clamped or bonded to a steel grid shell. The Great Court roof spans the museum's 6,100 m² (65,700 sq ft) courtyard with 3,312 individual panes, about 315 tonnes of glass in total, on a steel grid weighing 478 tonnes. It was designed by Foster + Partners, engineered by Buro Happold and built by Waagner-Biro.5 Its highest point is 26.3 m (86 ft) above the floor, and it rests on the surrounding walls on sliding bearings so that it can expand and contract.5 See thermal movement in metal roofs.

Glazing materials and code requirements

Glass inclined more than 15° from vertical is treated as sloped or overhead glazing, which is more vulnerable than vertical glass to impact from falling objects and hail, and more likely to fall out of its opening when broken.34

In the United States, the International Building Code and state codes based on it (section 2405) allow the following materials for sloped glazing:4

  • laminated glass with at least a 30 mil (0.76 mm) PVB or equivalent interlayer;
  • wired glass;
  • heat-strengthened or fully tempered glass;
  • approved light-transmitting plastics.

In multi-layer units, each layer must be one of these. Annealed glass is permitted only in certain exceptions.4 Where heat-strengthened or fully tempered glass is used alone, or as the bottom pane of an insulating unit, a screen is required beneath it. The screen must carry twice the weight of the glass, sit within 4 in (102 mm) of it, and be made of noncombustible wire of at least No. 12 B&S gauge with mesh no larger than 1 × 1 in (25 × 25 mm). Laminated glass needs no screen.4 Exceptions include low tempered glazing in houses and commercial greenhouses not open to the public.4

Skylights and sloped glazing on roofs flatter than 45° must be mounted on curbs at least 4 in (102 mm) above the roof, though unit skylights in one- and two-family houses may be curbless on roofs of at least 3:12 (14°).4 Framing in noncombustible building types must itself be noncombustible.4

Loads

Glass roofs are designed for wind, snow, dead and maintenance loads, and the glass is sized using standards such as ASTM E1300 in North America. Snow and dead loads are long-term loads, which matters because glass loses strength under sustained load. As a rule of thumb, the dead load of glass is its thickness in millimetres × 2.5 kg/m² (or thickness in inches × 13 lb/ft²), multiplied by the cosine of the roof angle.3

Slope, drainage and condensation

Patent glazing needs a minimum pitch of about 15° for rainwater to run off reliably.2 Gutters at the foot of sloping glazing, and internal condensation channels, drain both rain and condensation.2

Solar control and comfort

Large areas of overhead glass can cause overheating, glare and heat loss. Design considerations listed for patent glazing include heat gain and shading, natural and smoke ventilation, acoustics and security, as well as structure and drainage.2

Soffit intakeRidge exhaust Moving air removes heat in summerand moisture in winter.
How roof ventilation works

Access, cleaning and safety

Glass roofs need planned access for cleaning and maintenance. The Great Court roof, which cannot be walked on, is cleaned every three months over about two weeks by operatives harnessed to a network of safety cables.5 Rooflights should never be walked on unless specifically designed for it; for walk-on rooflights, glass to an appropriate specification is the only suitable material.6 See fragile roof and roofing fall protection.

Conservation of historic glass roofs

Historic glass roofs often have cast-iron rooflights or lead-clad steel glazing bars. Original cast-iron rooflights were often given secondary glazing at ceiling level to reduce draughts.1 Conservation work balances keeping historic bars and glass with the need for safety glazing, better thermal performance and weathertightness. Modern metal and timber rooflights perform much better thermally and against the weather than old ones.1

On the timeline

  1. mid 18th centuryRooflights appeared in Britain and most of Europe in the mid-18th century.
  2. mid 19th centuryMass-produced cast-iron rooflights followed in the mid-19th century, and survive most often over the stairwells of late Victorian and Edwardian terraced houses.
  3. 1851Examples include the Leeds Corn Exchange, the Oxford University Museum, and the Crystal Palace of 1851, which used overhead glazing on an unprecedented scale.
  4. 1950sAluminium, developed during the Second World War, became the main bar material in the 1950s and 1960s because of its lower weight and cost.
  5. 2000Large modern glass roofs on steel grids include the roof of the Queen Elizabeth II Great Court at the British Museum in London, opened on 6 December 2000.
See the full roofing timeline →

Sources

Reviewed 2 November 2026 · 6 sources · 6 cited inline · Editorial policy · Plain-text version · Suggest a correction

  1. RooflightingBuilding Conservation Directory · buildingconservation.com
  2. Patent glazingDesigning Buildings Wiki · designingbuildings.co.uk
  3. Specifying glass for sloped glazing and skylightsThe Construction Specifier · constructionspecifier.com
  4. 2025 California Building Code Section 2405: Sloped Glazing and SkylightsGoCodebook (California Building Standards Commission text) · gocodebook.com

From the community

Know this topic first-hand? Share a photo you took, a correction with a source, or local knowledge. Every contribution is reviewed before it appears.

Contribute to Glass Roof