A bowstring truss roof is a long-span roof supported by trusses whose top chord is curved like a bow and whose bottom chord is straight like the string. The result is a gently arched or barrel-shaped roof over a large room with no interior columns. Structurally, each truss works as a tied arch: the curved top chord carries roof load mainly in compression, while the bottom chord acts as a tension tie that stops the arch ends from spreading and pushing the walls outward.1
The form belongs to two families on roof.wiki. As a roof truss it is a specialised long-span type, quite different from the triangulated Fink or king post trusses used on houses. As a roof shape it is a timber-framed relative of the barrel vault roof, producing the same curved silhouette with a lightweight framework instead of masonry.
Structure and dimensions
A typical bowstring truss consists of:2
- a curved top chord, usually built up from two spliced or laminated pieces of lumber, sometimes three or four for extra strength;
- a horizontal bottom chord bearing on masonry pilasters or columns at each end;
- web members — vertical struts and diagonal ties — connected to the chords with pinned joints and gusset plates of cast iron, steel or wood, often with large bolts over 1 in (25 mm) in diameter;
- purlins spanning between trusses to carry the roof deck.
Bowstring trusses were built in wood, cast iron and steel. Common clear spans are 30-60 ft (9-18 m), and some exceed 100 ft (30 m); trusses may be spaced 10 ft (3 m) or more apart and up to 30 ft (9 m) apart along a wall. Span capacity rises with deeper chord lumber (for example 2x12 rather than 2x8) and with a taller arch rise (10 ft rather than 6 ft, 3 m rather than 1.8 m).2 Older ends were often joined with U-shaped steel straps and bolts tying top and bottom chords together.1
History
The bowstring form derives from bridge engineering: Squire Whipple patented a bowstring iron bridge truss in 1841.2 As a roof structure it was popular in North America from about 1900 to 1950, and most surviving examples are in buildings erected before the 1950s.2 The long, column-free space suited the new building types of the motor age and light industry: automobile garages and service stations, warehouses, factories, bowling alleys, roller and ice rinks, arenas and aircraft hangars.2 Many original designs were calculated with simple graphical methods that did not capture all the forces now known to act on the trusses.1
Failure modes
Bowstring roofs have a poor reputation among fire services and structural engineers because a single failure can lead to progressive collapse. Engineers investigating Chicago failures identify these main causes:1
- Overstress or loss of the bottom chord, the most critical member. If its splice or end connection fails, the arch spreads and pushes the supporting masonry outward.
- Weak supports — unreinforced clay masonry walls and pilasters with little capacity to resist outward thrust.
- Added loads — unbalanced snow drifts that turn tension webs into compression members, ponding water, wind uplift, and heavy new HVAC units placed on old roofs.
- Lower design values — wood tension values were revised downward after the In-Grade Testing Program of the 1980s, so trusses designed earlier may have less reserve than assumed.
Building inspectors add drainage failures at parapet troughs, where ponding water pushes the parapet outward and can separate the truss from its bearing; decay of wood members and gussets from leaks; and rust or fatigue of metal gussets and bolts.2 Water is heavy: a 1 in (25 mm) pool on a 20 x 20 ft (6 x 6 m) area weighs about 2,000 lb (900 kg).2 See also ponding water and snow load.
Fire hazard
In fires, the wide truss spacing means there may be no solid deck to support a firefighter, and the failure of one truss can bring down its neighbours, opening a hole 20 ft (6 m) or more across.2 Two Chicago firefighters died in a bowstring roof collapse at the Beverly Tire and Auto Center in 1998, and a 2010 collapse at a former laundry killed two more and injured 19; some fire departments have barred crews from entering bowstring-truss buildings during fires.1 Many jurisdictions require such trusses to be exposed or the building to be marked with an exterior placard.2
Inspection and maintenance
Common inspection guidance is to view trusses from below rather than walking on them, and to look for:2
- a straight, level bottom chord without crushing, cracking or decay at the bearings;
- a smooth, consistent arch in the top chord with no sags or bellies;
- trusses that line up straight when viewed along the building, without twisting;
- intact gussets with all large bolts present;
- plumb, uncracked pilasters and columns, and any water staining or efflorescence on timber or masonry.
Routine inspections about every five years are recommended, and the most frequent abuse found is equipment hung from the bottom chord — trusses should never be cut, modified or used to hang loads without engineering.2 Keeping roof drains, gutters and parapet scuppers clear is essential (see roof drain and scupper).2
Repair and strengthening
When a bowstring truss has failed or deformed, engineers treat the roof and walls as one system. A documented Chicago repair after a 2025 collapse of a retail building followed this sequence: shore every truss on posts; survey the geometry, including a LIDAR scan of the masonry; model the truss and wall; jack the truss back toward its original shape in about 47 controlled increments over two days; replace the failed bottom-chord section with pressure-treated glulam; add bolted steel angles to overstressed top chords; install steel channels, rods and turnbuckles to restore tie action; and clamp the bulging pilaster between steel channels tied back to the truss.1 The central question in any evaluation is whether the truss can still act as a tied arch.1
Re-roofing bowstring roofs
The curved roof is typically sheathed in timber boards or plywood on purlins and covered with roll roofing, built-up roofing or modified bitumen, and more recently with single-ply membranes that follow the curve. Because many of these roofs have little spare capacity, re-roofing is an occasion to check structure: tearing off rather than adding layers keeps dead load down, new rooftop equipment should be placed only after engineering review, and drainage at the low edges and parapet troughs should be improved to prevent ponding.12 Inspectors should not walk on the trusses themselves, and roofers working on the deck need fall protection because the curved surface steepens toward the eaves.2
Where they are found
Bowstring truss roofs survive in large numbers in older industrial and commercial districts across the United States and Canada, especially in cities like Chicago where pre-war garages, laundries and shops line commercial streets.12 A heavy snowfall in February 2021 caused several old Chicago buildings to fail, including some with bowstring roofs.1
On the timeline
- 1841The bowstring form derives from bridge engineering: Squire Whipple patented a bowstring iron bridge truss in 1841.
- c. 1900As a roof structure it was popular in North America from about 1900 to 1950, and most surviving examples are in buildings erected before the 1950s.
Sources
Reviewed 2 November 2026 · 2 sources · 2 cited inline · Editorial policy · Plain-text version · Suggest a correction
- Lessons from Bowstring Truss Failures in ChicagoSTRUCTURE magazine (NCSEA) · structuremag.org
- What Inspectors Should Know About Bowstring TrussesCertified Commercial Property Inspectors Association (CCPIA) · ccpia.org