# R-Panel and PBR Panel

> The standard North American through-fastened steel panel: 36 in (914 mm) wide with 1 1/4 in (32 mm) trapezoidal ribs at 12 in centres, able to span purlins; PBR adds a purlin-bearing leg at the side lap.

- URL: https://roof.wiki/r-panel/
- Topic: Roofing Materials
- Also known as: R panel; PBR panel; purlin bearing rib panel; R-panel roofing; PBR roofing; RPanel
- Regions: North America
- First published: 2026-11-02 · Last reviewed: 2026-11-02
- Cite as: "R-Panel and PBR Panel." roof.wiki. https://roof.wiki/r-panel/

## Key facts

- **Coverage width:** 36 in (914 mm)
- **Rib height and spacing:** 1 1/4 in (32 mm) at 12 in (305 mm) centres
- **PBR meaning:** Purlin bearing rib: extra flat leg at the side lap
- **Gauges:** 26 standard; 24 and 22 optional
- **Minimum slope:** 1/2:12 with side-lap sealant; 3:12 without
- **Typical purlin span:** Up to about 5 ft (1.5 m)
- **Main use:** Pre-engineered metal buildings, agricultural and light commercial

R-panel is the generic trade name for the most widely used exposed-fastener metal roof and wall panel in North America: a roll-formed steel sheet that covers 36 in (914 mm), with major trapezoidal ribs 1 1/4 in (32 mm) high at 12 in (305 mm) centres and small stiffening ribs in the flats between them.[1][2] PBR (purlin bearing rib) panel is a near-identical profile with an extra flat landing, the purlin-bearing leg, on the underlapping edge of each sheet, which supports the side lap where it crosses a purlin.[3][2] The two names are often used interchangeably in the trade.

R-panel is a sub-topic of [through-fastened metal panels](/wiki/through-fastened-metal-panels). Within that family it is the deepest and strongest of the common light-gauge profiles, deep enough to span open purlins without a deck. By contrast, 5V crimp has only 1/2 in (13 mm) crimps and needs solid decking, and 7/8 in corrugated has rounded waves 2.67 in (68 mm) apart.[1][4]

## Profile and the purlin-bearing leg

Both profiles share the 36 in coverage, 1 1/4 in rib height and 12 in rib spacing.[1][2] The difference is at the edge where one sheet overlaps the next. On a PBR panel the underlapping rib has a wider flat base that sits on the purlin, while an R-panel's edge rib has a sharper base angle.[3] On a purlin-framed building the purlin-bearing leg helps support the lap so that fasteners there pull through less readily; over solid decking the difference is marginal, and the two panels look almost identical from the ground.[3] Some manufacturers offer purlin-bearing legs as an option on their standard profile.[2]

## Materials

R-panel and PBR are roll-formed from coil-coated steel:

- **Gauge.** 26 gauge (about 0.018 in or 0.46 mm) is standard; 24 gauge (about 0.024 in or 0.61 mm) and 22 gauge are offered for higher loads, wind or hail.[2][3]
- **Steel grade.** In one Texas windstorm evaluation, 26-gauge panels are made from ASTM A792 or A653 structural steel Grade 80 and 24-gauge from Grade 50.[5]
- **Metallic coating.** Aluminium-zinc AZ50 or AZ55 to ASTM A792, or galvanised G90 to ASTM A653.[5]
- **Paint.** Silicone-modified polyester and PVDF paint systems, or bare aluminium-zinc.[2]

Aluminium R-panels exist but are uncommon; most are steel.

## Uses

R-panel and PBR are the default cladding of pre-engineered metal buildings: warehouses, workshops, agricultural buildings, equipment sheds, riding arenas, self-storage, churches and light industrial buildings, used on both roofs and walls.[2][3] They are also used on budget and "modern farmhouse" or industrial-style houses over solid decking.[3] Over purlins, an R-panel can typically span up to about 5 ft (1.5 m), depending on gauge and design load.[3][5] Some panels are supplied with a factory-applied anti-condensation fleece on the underside for uninsulated buildings.[2]

## Installation

Panels are laid from the eave toward the ridge and across the roof, each sheet lapping the previous one at the edge rib. A typical high-wind evaluation for 26-gauge PBR over open steel purlins sets out the essentials:[5]

- **Supports.** Open steel purlins or girts of at least 16 gauge.
- **Panel-to-purlin fasteners.** No. 12-14 by 1 1/4 in hex-head self-drilling screws with sealing washers in a line along each purlin, in a 12-12-12 in pattern (beside each major rib and in the flats), with at least three threads through the steel.
- **Panel ends and end laps.** The same screw type and pattern.
- **Side laps.** 1/4-14 by 7/8 in hex-head lap (stitch) screws with sealing washers at 20 in (508 mm) centres.
- **Design capacity.** In that evaluation, allowable negative (uplift) pressure for 26-gauge panels ranges from about 36 psf (1.7 kPa) with purlins at 5 ft centres to about 109 psf (5.2 kPa) at 2 ft centres.

Over wood framing or decking, wood-grip screws are used and must engage solid framing; screws that catch only thin sheathing have little pull-out resistance in high wind.[3] Wind-zone schedules typically call for screws at every rib in edge and corner zones and at every other rib in the field.[3] Near salt water, stainless-steel fasteners are recommended.[3]

## Minimum slope and sealing

The published minimum slope depends on how the laps are sealed. One manufacturer lists PBR down to 1/2:12 (about 2.4 degrees).[2] The Texas evaluation allows 1/2:12 only where sealant is used in the side laps, and requires 3:12 (14 degrees) without sealant.[5] These figures follow the International Building Code rule that lapped, non-soldered metal panels need 3:12 without lap sealant and 1/2:12 with it.[6] On low slopes, end laps are sealed with tape mastic and outside closures (foam or metal) seal the ribs at eaves and ridges.

Watertightness at each fastener relies on the neoprene or EPDM washer under the screw head; these washers age in sunlight and may crack after 15 to 20 years, so periodic inspection and refastening are part of normal maintenance.[3]

## Comparison with standing seam

R-panel and PBR are the lowest-cost common metal roof systems, but they are through-fastened: every screw pierces the panel, and the panel cannot slide on its fixings as it expands and contracts. On long runs this loads the fasteners and can elongate holes.[7] Structural standing-seam systems used on the same metal buildings have concealed clips that allow movement and are rated for slopes as low as 1/4:12.[6] As a result, R-panel tends to be used on smaller and lower-budget buildings and on walls, and standing seam on large, low-slope roofs where long-term weathertightness matters most.

## Failure modes

Common problems with R-panel and PBR roofs are:

- **washer degradation and fastener back-out**, leading to leaks at screw heads;[3]
- **missed or stripped fasteners**, especially screws that miss the purlin;
- **side-lap leaks** on low slopes where sealant was omitted;[5]
- **elongated holes** at the ends of long sheets from thermal movement;[7]
- **condensation drip** in uninsulated buildings, addressed with underside fleece or insulation;[2]
- **cut-edge and scratch corrosion**, particularly near the coast, where stainless fasteners and suitable coatings are advised.[3]

Retrofit is common: worn R-panel roofs are often re-screwed with oversized fasteners, coated with elastomeric or silicone roof coatings, or overlaid with new panels on sub-framing.

## Sources

1. Most Commonly Used Metal Roofing Profiles — Swenson Shear / Southern Tool. https://www.southern-tool.com/store/cms//0/Swenson-Most-Commonly-Used-Metal-Roofing-Profiles-.pdf
2. PBR Panel — MBCI. https://mbci.com/products/pbr
3. Exposed-fastener panel types — Southern Metal Roof. https://3-southern-metal-roof.pages.dev/exposed-fastener/panel-types
4. 5V Crimp — MBCI. https://www.mbci.com/products/5v-crimp/
5. RC-666: PBR Steel Panels Installed over Steel Purlins or Steel Girts — Texas Department of Insurance. https://tdi.texas.gov/Wind/prod/rc/rc666.pdf
6. Metal panel roof systems — Professional Roofing (NRCA). https://professionalroofing.net/articles/article/4956
7. TB702 Sheet Expansion — Fabral. https://fabral.com/tb702-sheet-expansion