# Pitch Pocket (Pitch Pan)

> An open sheet-metal or plastic box flashed into a low-slope roof around an irregular penetration and filled with grout and pourable sealer; a recognised maintenance item.

- URL: https://roof.wiki/pitch-pocket/
- Topic: Low-Slope & Flat Roof Systems
- Also known as: pitch pan; gum pocket; penetration pocket; sealant pocket; pourable sealer pocket
- Regions: North America, Global
- First published: 2026-11-02 · Last reviewed: 2026-11-02
- Cite as: "Pitch Pocket (Pitch Pan)." roof.wiki. https://roof.wiki/pitch-pocket/

## Key facts

- **Also called:** Pitch pan, gum pocket, penetration pocket
- **Minimum height (NRCA):** 4 in (102 mm) above the roof
- **Minimum flange width (NRCA):** 4 in (102 mm)
- **Minimum metal (NRCA details):** 26-gauge galvanised steel
- **Fill (NRCA):** Half non-shrink grout, topped with compatible pourable sealer
- **NRCA position:** Not the preferred flashing method

A pitch pocket, also called a pitch pan, gum pocket or penetration pocket, is an open-topped sheet-metal or prefabricated plastic box set around an irregular penetration through a low-slope roof, flashed into the roof membrane by its flanges, and filled with grout and sealant so that the penetration is sealed where it passes through the roof. Pitch pockets are used where a penetration's shape, such as a structural steel angle, I-beam, a cluster of conduits, a U-shaped bracket or an oval support, makes it impractical to wrap a conventional membrane flashing around it.[1]

Pitch pockets are one of the families of detail used to flash penetrations in [low-slope roofs](https://roof.wiki/low-slope-roof/), and a specialised form of [roof flashing](https://roof.wiki/roof-flashing/). They differ from their siblings in relying on a poured sealant, rather than a bonded flashing membrane and a separate metal counterflashing, to keep water out: pipe boots and sleeves are prefabricated flashings fitted around round pipes; [roof curbs](https://roof.wiki/roof-curb/) raise the opening above the roof and are base-flashed like a wall; and [base flashing](https://roof.wiki/base-flashing/) seals upstands. Because the sealant is exposed to sunlight and movement, the pitch pocket is widely regarded as the least durable of these options.[1][2]

## Construction and dimensions

A traditional pitch pocket is a square or rectangular box of sheet metal with:

- **Walls** at least 4 in (102 mm) high above the roof surface, according to guidance published by the National Roofing Contractors Association (NRCA);[1]
- **Horizontal base flanges** at least 4 in (102 mm) wide, which are set on the roof membrane and stripped in with membrane flashing plies;[1]
- **Hemmed exposed edges** and **soldered corner seams**, so the box itself is watertight;[1]
- **Metal** of at least 26-gauge galvanised steel in NRCA's details, or the material recommended by the membrane manufacturer;[1]
- a **sheet-metal rain collar** fixed around the penetration above the pocket and overlapping its top, so that water running down the penetration is shed outside the fill. All NRCA pocket details include such a collar.[1]

On asphaltic built-up, coal-tar and modified bitumen roofs, the metal flanges are primed and set in mastic before being stripped in; some thermoplastic membrane manufacturers require pockets made of membrane-coated metal so that the flanges can be heat-welded to the field sheet.[1] Prefabricated pockets of moulded plastic, often split so they can be fitted around an existing penetration, are made for single-ply roofs.

## Filling

The traditional fill was hot pitch, asphalt or a solvent-based mastic, which shrank, cracked and lost adhesion as it aged.[2] Current NRCA guidance is to half-fill the pocket with a non-shrink cementitious grout to form a solid base and stop the topping from running down between the penetration and the deck, and then to top off with a pourable sealer compatible with the roof membrane or recommended by its manufacturer.[1] Some single-ply manufacturers instead call for the whole pocket to be filled with their pourable sealer, with no grout, insulation or granules, after all surfaces are cleaned and primed with the correct membrane primer; such sealers may skin over in under 30 minutes but take weeks to cure through their full depth.[3] Silicone, roof cement and asphalt primer are not compatible with these sealers.[3]

In the field, poor practice is common: pans have been filled with sand, rocks, foam or old roofing, or with mortar that can shrink by as much as 5 per cent, leaving gaps for water to enter.[2]

## Installation steps

1. **Check whether a pocket is really needed.** If the penetration can be relocated, combined into a curb, or fitted with a prefabricated boot or sleeve, those options are preferred.[1][4]
2. **Prepare the penetration.** Clean it of rust, paint, oil and dirt, and seal the gap between the penetration and the deck so that sealer cannot run through.[2]
3. **Set the pocket** on the membrane in mastic or adhesive, with enough clearance between the penetration and the walls for sealer to surround it completely.
4. **Strip in the flanges** with membrane flashing plies or welded membrane.[1]
5. **Fill the pocket** with grout and pourable sealer as specified, and leave it undisturbed while it cures, avoiding rain.[1][2][3]
6. **Fit the rain collar** above the pocket.[1]

## Why pitch pockets are a maintenance item

NRCA states that penetration pockets are not the preferred flashing method, that they can be a constant maintenance problem, and that poor or missing maintenance is likely to lead to leaks; most roof system manufacturers object to them in their warranties.[1] An industry chemist writing in the journal of the roof consultants' institute described pitch pans as "perpetual maintenance items" and noted that NRCA discourages them because of poor workmanship and high failure rates.[2] The main reasons are:

- **Shrinkage and cracking** of fill materials, which opens a gap against the penetration or the pocket wall.[2]
- **Loss of adhesion** where the penetration was not cleaned or primed, or where incompatible primers and mastics were used.[2][3]
- **Ultraviolet exposure** of the sealer surface.
- **Movement** of the penetration relative to the roof, from vibration, thermal expansion or structural deflection.
- **Ponding** inside the pocket where the sealer has settled below the rim, letting water stand against the joint.
- **Missing rain collars**, so that water running down the penetration flows straight into the joint.[1]

Pockets should be checked at every routine roof inspection and topped up with compatible sealer whenever the fill has shrunk, cracked or pulled away.

## Alternatives

- **Prefabricated penetration seal kits.** Packaged systems with round, precast curbs about 2 in (50 mm) high and 2 in wide, bonded to the roof with moisture-cure adhesive and filled with single-component sealant, need no metal flashing or fasteners. Round shapes use the least sealer and expose the smallest surface; one author reports installation in under ten minutes, or under five with newer polyether sealants.[2] These kits do not bond well to some smooth membranes such as TPO and smooth APP modified bitumen without special preparation.[2] One manufacturer's kit for asphaltic roofs, for example, uses 2 in (51 mm) high polyester or urethane curb segments in half-rounds, straights and corners, bonded with a moisture-curing polyether adhesive, set with at least 1 in (25 mm) of clearance around the penetration and filled with a 2 in layer of self-levelling polyether sealant; it calls for a surface temperature of at least 4.4 °C (40 °F) and rising, no rain for four hours, and a granulated cap sheet extending 6 in (152 mm) around the curb on smooth APP roofs.[5]
- **Prefabricated boots and sleeves** for round pipes and conduits, flanged and bonded or welded to the membrane, which are preferable to field-wrapping penetrations.[4]
- **Curbs and equipment rails.** Grouping pipes and conduits through a curbed opening with a hood, or supporting equipment on raised rails with flashed posts, avoids multiple small pockets.
- **Relocating penetrations.** Keeping penetrations at least 2 ft (600 mm) from walls, curbs and each other allows them to be flashed properly.[4]

## History

The traditional pitch pan on built-up roofs was a flanged metal box about 4 in (100 mm) high, screwed to the roof, filled with non-shrink grout and topped with solvent-based asphalt mastic, sometimes with a rain cap.[2] With the rise of single-ply membranes, smaller pans with 2 in (50 mm) metal flanges filled with two-part urethane sealer became common; these performed better than mastic but took up to an hour to flash and were labour-intensive to mix, leading to today's single-component pourable sealers and prefabricated kits.[2]

## Sources

1. Manual Elements: Penetration pockets — Professional Roofing (NRCA). https://professionalroofing.net/Articles/Penetration-pockets/630
2. Interface, September 2001 (Georgeau, penetration seals) — IIBEC (formerly RCI). https://iibec.org/wp-content/uploads/2001-09-georgeau-2.pdf
3. One-Part Pourable Sealant Application Tips (RS-2377) — Johns Manville. https://www.jm.com/content/dam/jm/global/en/commercial-roofing/brochures/RS-2377%20JM%20One-Part%20Pourable%20Sealant%20Application%20Tips.pdf
4. Technical Details: Elements of Proper Flashing Applications — Roofing Contractor. https://www.roofingcontractor.com/articles/86728-technical-details-elements-of-proper-flashing-applications
5. M-Curb Pitch Pocket System data sheet — GAF. https://www.gaf.com/en-us/document-library/documents/data-sheets/m-curb-pitch-pocket-system-datasheet-comas100.pdf