# Horizontal Seam Roofing (Bermuda Seam)

> A sheet-metal roof in which long pans run across the slope rather than up it, locked into one another at stepped horizontal nailers so the roof reads as a series of strong horizontal bands.

- URL: https://roof.wiki/horizontal-seam-roofing/
- Topic: Installation & Methods
- Also known as: horizontal seam roof; Bermuda seam; Bermuda roof; Bermuda-type metal roof; stepped seam roofing; horizontal batten roof
- Regions: North America, Europe, Global
- First published: 2026-11-02 · Last reviewed: 2026-11-02
- Cite as: "Horizontal Seam Roofing (Bermuda Seam)." roof.wiki. https://roof.wiki/horizontal-seam-roofing/

## Key facts

- **Pan orientation:** Long dimension horizontal, across the slope
- **Steep-pitch details:** Slopes of 6 in per ft (1:2, about 27°) or more
- **Special design needed:** Below 4 in per ft (1:3, about 18°) or in snow, ice and heavy rain
- **Typical copper:** 16 oz (0.55 mm) for pans up to 18-1/2 in; 20 oz (0.68 mm) for wider pans
- **Standard lock:** 3/4 in (19 mm) lock at each stepped nailer
- **Long-run movement:** Expansion joints or vertical battens every 30–40 ft (9–12 m)
- **Industry name:** Bermuda seam (NRCA glossary)

Horizontal seam roofing is a family of sheet-metal roof systems in which the metal pans are laid with their long dimension running across the roof, parallel to the eaves, instead of running from eaves to ridge as in a standing seam or batten seam roof. Each pan is fixed to a horizontal wood nailer and locks into the pan below at a small step, so the finished roof shows a series of crisp horizontal shadow lines rather than vertical ribs.[1] In North American trade usage the stepped version is called a Bermuda seam: the National Roofing Contractors Association defines it as a metal panel profile with a step-down that runs perpendicular to the slope, giving a shingle-like appearance that sheds water.[3]

The system is most closely associated with copper, and the most detailed public design guidance comes from the Copper Development Association (CDA) Architectural Handbook, but the same principle is also used in prepainted steel, including roll-formed panels sold as "Bermuda" profiles.[1][4]

## How it differs from other metal roof systems

Under the parent topics of metal roofing and copper roofing, horizontal seam roofing sits between two better-known systems:

- **Standing seam and batten seam roofs** run their seams up the slope, so water flows parallel to the joints and never has to cross them. That is why they work on lower slopes and over long runs.
- **Flat seam roofing** uses small, nearly square sheets with folded and usually soldered seams on all four sides, and is suited to very low slopes and curved surfaces.
- **Horizontal seam roofing** turns long pans sideways. Every horizontal joint is a lap that water must flow over, so the joint relies on the height of the step, the depth of the lock and the slope of the roof to stay weathertight.[1]

The trade-off is visual. A horizontal seam roof emphasises the width of a building and the courses of the roof, much like slate or shingle courses, while a standing seam roof emphasises height. That makes the horizontal system popular on mansards, fascias, towers and steep feature roofs where the metal is very visible.[4]

## Components and specifications

The CDA describes the assembly as copper pans attached to horizontal wood nailers fixed to the deck, with a step at each nailer where the adjacent pans lock together. The height and spacing of the steps can be varied, and extra intermediate steps can be formed between the locks to change the scale of the pattern. Between the nailers the pans can be supported on rigid insulation set flush with the nailers or on wood sheathing laid over them. Any smooth, flat deck is acceptable.[1]

In general CDA guidance, copper roofing is normally made from 16 oz or 20 oz cold-rolled sheet, about 0.55 mm (0.0216 in) and 0.68 mm (0.027 in) thick. The pans bear on a slip sheet of rosin-sized building paper of at least 4 lb per 100 ft² laid over at least 30 lb saturated roofing felt, and where nailers are used they should usually run perpendicular to the seams.[2]

The handbook gives a sheet and pan table based on a 1-1/2 in (38 mm) step height:[1]

| Sheet width | Pan width, steep pitch | Pan width, low pitch | Copper |
|---|---|---|---|
| 18 in (457 mm) | 14-1/2 in (368 mm) | 10-1/4 in (260 mm) | 16 oz |
| 20 in (508 mm) | 16-1/2 in (419 mm) | 12-1/4 in (311 mm) | 16 oz |
| 22 in (559 mm) | 18-1/2 in (470 mm) | 14-1/4 in (362 mm) | 16 oz |
| 24 in (610 mm) | 20-1/2 in (521 mm) | 16-1/4 in (413 mm) | 20 oz |
| 26 in (660 mm) | 22-1/2 in (572 mm) | 18-1/4 in (464 mm) | 20 oz |
| 28 in (711 mm) | 24-1/2 in (622 mm) | 20-1/4 in (514 mm) | 20 oz |

The exposed pan width shrinks on low-pitch work because each pan must reach further up onto the next step to keep wind-driven water out. Wider pans move to the heavier 20 oz sheet to resist buckling and oil-canning.[1]

Factory-formed steel versions follow the same geometry with different numbers. One North American roll-formed Bermuda panel, for example, is made in 24-gauge steel with an 11 in (279 mm) coverage and a 1 in (25 mm) seam, factory lengths to 30 ft (9.1 m), and concealed anchor clips at about 20 in (508 mm) centres over solid sheathing, roughly 90 clips per roofing square.[4]

## Slope limits

Because the seams cross the flow of water, slope matters more than for standing seam. The CDA's standard steep-pitch details apply to roofs of at least 6 in per ft (1:2, about 27°). Roofs below 4 in per ft (1:3, about 18°), and roofs of any slope in areas with ice, snow or heavy rain, are treated as special conditions that need extra design measures from the handbook's section on special roofing considerations.[1] Between those two values the low-pitch details apply.

## Installation

The CDA gives two basic seam details.[1]

1. **Steep pitch.** Each pan is joined to the next with a 3/4 in (19 mm) lock. Cleats are nailed to the wood nailer, and the lock is laid down against the vertical face of the nailer so that it sits in the shadow of the step.
2. **Low pitch.** The lower pan has a 3/4 in (19 mm) lock and runs at least 4 in (102 mm) up onto the next higher step, where it is held by cleats. The lower edge of the upper pan is folded under 3/4 in (19 mm) and hooked over the locking edge of the lower pan, and the lock again lies against the nailer face.

Where the slope changes without a step, adjacent pans are joined with a seam like a normal low-slope transverse seam, with cleats fixed to the nailers at 12 in (305 mm) centres; where there is a step, the steep-pitch lock is used instead. Valleys use a continuous valley batten at least 4 in (102 mm) higher than the neighbouring nailers. An extra copper strip 4 in wide extends at least 6 in (152 mm) onto the nailers, insulation or sheathing, ends in a 1/4 in (6 mm) dam, and its lower edge is soldered to the pans below.[1]

## Thermal movement

Copper pans expand and contract with temperature. In a horizontal seam roof the steps and locks absorb movement up and down the slope. Along the length of each pan, the CDA calls for expansion joints or vertical battens in runs of 30 to 40 ft (9 to 12 m), and its transverse expansion seam detail uses a 1 in (25 mm) lock double-folded 6 in (152 mm) from the end of one pan, with a 3/4 in fold receiving a locked cleat and the next pan hooked into it. Expansion seams on neighbouring courses must be staggered so that the metal does not build up into a thick, stiff lump at the locks.[1] Under the handbook's general guidance, pans up to about 10 ft (3 m) are treated as short pans, and longer ones need added allowance for movement at their ends.[2]

## Performance, maintenance and failure modes

A correctly detailed horizontal seam roof in copper behaves much like any other copper roof, and the main maintenance task is keeping valleys, gutters and the steps clear of debris. The system's specific weaknesses come from its geometry:

- **Back-flow at the steps.** Each step is a horizontal lap. On slopes below the recommended values, or where snow and ice dam against the step, water can be driven up and over the lock. This is why the CDA treats low slopes and severe climates as special conditions.[1]
- **Restrained expansion.** Long pans without the recommended expansion joints or battens can buckle or tear at fixings.
- **Thick locks.** Unstaggered expansion seams create bulky joints that are hard to close and can open up later.[1]
- **Valley and intersection detailing.** Valleys, hips and changes of slope interrupt the courses and rely on battens, dams and soldered joints. These are the usual places where leaks start.

## Use and history

Horizontal and stepped metal roofs are mostly used where the roof is part of the architecture: steep residential roofs, mansards, dormer cheeks, turrets and commercial fascias. Manufacturers market factory-formed versions for roofs, fascias, mansards and siding on residential, commercial and institutional buildings.[4]

The name refers to Bermuda, where white, stepped roofs are a defining feature of the island's traditional houses and are closely tied to collecting rainwater on an island without natural freshwater sources.[5] The sheet-metal Bermuda seam borrows that stepped appearance and adapts it to locked metal pans.[3] Today copper versions are typically custom work by architectural sheet-metal shops following CDA details, while steel versions are roll-formed panels with concealed clips.[1][4]

## Sources

1. 8.6 Horizontal Seam Roofing — Copper Development Association. https://copper.org/applications/architecture/arch_dhb/arch-details/roofing/hor_seam_roofing.php
2. Roofing Systems – Introduction (Architectural Handbook, section 8) — Copper Development Association. https://www.copper.org/applications/architecture/arch_dhb/arch-details/roofing/
3. Roofing Guidelines Glossary: Bermuda seam — National Roofing Contractors Association. https://www.nrca.net/RoofingGuidelines/Glossary/detail/78
4. Bermuda Panel — Berridge Manufacturing Company. https://www.berridge.com/products/alternative-systems/bermuda-panel
5. How the White, Stepped Roofs of Bermuda Allowed Residents to Live Without Fresh Water Sources — ArchDaily. https://www.archdaily.com/802423/how-the-white-stepped-roofs-of-bermuda-allowed-residents-to-live-without-fresh-water-sources