## Key facts

- **Main materials:** Glass, polycarbonate, acrylic, GRP sheet, ETFE foil
- **Sloped glazing (IBC):** Glass 15° or more from vertical; IBC Section 2405
- **Minimum laminated interlayer (IBC):** 0.75 mm (0.030 in) PVB or equivalent
- **Glass dead load:** About 2.5 kg/m² per mm of thickness (≈13 lb/ft² per inch)
- **Typical minimum pitch, bar systems:** About 15°
- **UK code of practice:** BS 5516-1:2004 (patent and sloping glazing)
- **ETFE weight:** About 1% of glass

A glazed roof is any roof, or part of a roof, covered with a transparent or translucent material so that daylight reaches the space below. The term spans everything from a single glass pane set among clay tiles on a barn to the iron-and-glass sheds of Victorian railway termini, modern structural-glass atrium roofs, plastic rooflights on warehouses and the inflated foil cushions over stadiums and botanic domes. What unites them is that the roof covering does two jobs at once: it must keep out rain, wind and snow like any other roof, and it must transmit light without letting in too much heat, losing too much heat, or endangering people underneath if it breaks.

Glazed roofing sits alongside individual rooflights such as the [skylight](https://roof.wiki/skylight/) and the [roof lantern](https://roof.wiki/roof-lantern/), and includes the bar-supported systems known as [patent glazing](https://roof.wiki/patent-glazing/). Opaque roofs pierced by small rooflights are usually treated as ordinary roofs with components; a glazed roof in the fuller sense is one where the light-transmitting surface makes up a whole bay, ridge, vault or roof plane.

## Origins and development

Rooflights became common in Britain and much of Europe in the middle of the eighteenth century, once glassmakers could supply reasonably large sheets cheaply.[1] The earliest form was simply a sheet of glass laid into a tiled or slated roof in place of a tile, which admitted light but could not be opened, was awkward to clean and was used mostly on farm and secondary buildings.[1] Larger panes were preferred because many small panes joined with glazing bars or lead cames tended to leak.[1] Through the eighteenth and early nineteenth centuries an excise duty charged on glass by weight encouraged small, thin panes, which is one reason dormers and raised lantern lights were the usual way of lighting stairs and attics in that period; Robert Adam, for example, placed lanterns over grand halls and staircases.[1] When the glass duties were abolished in 1845, improved and cheaper glass helped open the way to much larger overhead glazing.[1]

The Victorian period produced the great glass roofs. The Crystal Palace of 1851 used overhead glazing on a scale never seen before, and railway stations, museums, corn exchanges and winter gardens followed.[1] To roof such areas economically, engineers developed glazing systems in which glass rested on metal bars and was held mechanically rather than bedded in putty; because so many inventors protected their versions, these became known collectively as patent glazing.[2] One London firm, founded on William Edgcumbe Rendle's 1870 patent, was still described as glazing contractors to the railways in 1911.[5] Mass-produced cast-iron rooflights also appeared in the mid-nineteenth century and stayed in domestic use for over a hundred years.[1]

In the twentieth century, lead-covered steel glazing bars gave way to aluminium sections, which became the dominant material in the 1950s and 1960s after wartime growth in aluminium production.[2] Insulating glass units, coated low-emissivity and solar-control glass, plastics such as polycarbonate and acrylic, glass-reinforced polyester sheet and, from the late twentieth century, ethylene tetrafluoroethylene (ETFE) foil have broadened what a glazed roof can be.[4]

## Main types

**Patent glazing and sloped glazing systems.** Glass panes are supported along two edges by bars running down the slope and fixed to purlins or rafters. The bars carry their own weight and the wind and snow loads on the glass but do not stiffen the building.[2] Channels in each bar collect any rain that gets past the outer seal, together with condensation, and drain it to the outside, which is why such systems are usually laid at about 15° or more.[2]

**Framed and structural glass roofs.** Atrium and courtyard roofs often use four-edge-supported insulating glass units in aluminium or steel framing derived from curtain walling, or point-fixed and bonded "structural" glass with minimal visible framing. These are typically engineered to the same load codes as other roof elements.

**Rooflights and lanterns.** Individual units set into an opaque roof: fixed or opening skylights, conservation rooflights that sit flush in slate or tile, flat-glass rooflights on flat roofs, domed plastic rooflights and raised [roof lanterns](https://roof.wiki/roof-lantern/).[1]

**Plastic sheet roofs.** Profiled and multiwall [polycarbonate sheet](https://roof.wiki/polycarbonate-roofing-sheet/), acrylic domes and [GRP rooflight sheets](https://roof.wiki/grp-fibreglass-roofing/) are lighter and more impact-resistant than glass and are common on industrial buildings, carports, verandas and greenhouses. They are often profiled to match adjacent [corrugated](https://roof.wiki/corrugated-roofing/) or trapezoidal metal sheets so that they can be lapped into the same roof.

**ETFE foil.** Two or more layers of ETFE film are welded into cushions held in aluminium extrusions and kept inflated by a small blower unit. ETFE weighs roughly one per cent as much as glass and can transmit up to about 95 per cent of visible light.[4] The material was first made by DuPont for aerospace insulation and was taken up for building envelopes in the early 1980s; the biomes of the Eden Project in Cornwall, completed in 2000, are a well-known example.[4] Inflation pressure can be raised in high winds or under snow.[4] It is related to, but distinct from, the coated-fabric [tensile membrane roof](https://roof.wiki/tensile-membrane-roof/).

## Safety glazing and loads

Overhead glass carries a particular risk: if it breaks, fragments fall onto people below. In the United States, the International Building Code treats glass inclined 15° or more from vertical as sloped glazing, regulates it under Section 2405 together with skylights, and covers the wind, snow, seismic and dead loads on it under Section 2404.2.[3] Permitted materials include laminated glass with a polyvinyl butyral (PVB) or equivalent interlayer at least 0.75 mm (0.030 in) thick, fully tempered glass, heat-strengthened glass, wired glass and approved plastics.[3] Where tempered or other non-laminated glass slopes more than 30° from vertical and is 3 m (10 ft) or more above a walking surface, the code generally requires a protective screen beneath it, a requirement that falls away for laminated glass with the minimum interlayer.[3] Similar thinking runs through European and British practice, where laminated glass on the inner pane of an overhead insulating unit is widely used so that a broken pane stays in place.[2]

Glass is heavy: 1 mm of thickness weighs about 2.5 kg per square metre, so a 1 in (25 mm) thickness weighs roughly 13 lb per square foot.[3] Designers must also allow for drifting snow, which can build up where a glazed roof meets a taller wall.[3] In the UK, BS 5516-1:2004 is the code of practice for designing and installing patent glazing and sloping glazing.[2]

## Thermal performance, condensation and solar gain

A glazed roof faces the sky and so loses heat faster at night and gains more heat from the sun by day than a vertical window of the same specification. Historic single glazing on iron or lead-covered bars insulates poorly and suffers heavy condensation in cold weather; patent glazing bars were therefore designed with condensation channels that lead moisture to the outside rather than letting it drip.[2] Modern systems use double or triple insulating glass units with low-emissivity and solar-control coatings, thermally broken aluminium framing, and in some cases fritted glass, internal blinds or external shading.[2] Overheating is a frequent complaint in conservatories and atria, and the design checklist for patent glazing explicitly includes heat build-up and shading alongside movement, acoustics and security.[2] Opening vents in glazed roofs can also double as natural ventilation and smoke ventilation.[2]

## Drainage and weathering

Because glass and plastic cannot be nailed or lapped like tiles, a glazed roof relies on continuous gaskets, cappings, sealants and drained frames. Rain that bypasses the outer seal must be collected inside the frame and drained out at the eaves, so the arrangement of laps, end stops and weep holes matters as much as the glass itself.[2] A shallow slope slows run-off, leaves dirt behind and increases the chance of water ponding against transoms; this is one reason two-edge-supported systems are usually laid steeper than about 15°.[2] Where glazing meets opaque roofing, the junctions are made with metal or [lead flashing](https://roof.wiki/lead-flashing/), with kerbs or upstands on flat roofs, as for any other penetration.

## Maintenance and common failures

Typical problems include degraded gaskets and sealants, failed seals in insulating units (shown by misting between panes), cracked glass caused by thermal stress or impact, blocked condensation channels, corrosion of steel bars or fixings, yellowing or embrittlement of older plastics, and leaks at the junctions with surrounding roofing. Safe access for cleaning and repair needs to be planned at design stage, since glass roofs are generally not walkable without crawl boards or fixed walkways.[2] Rooflights are a recognised hazard for falls through fragile surfaces on industrial roofs.

## Conservation

Historic glazed roofs, from Georgian lantern lights to Victorian station sheds, are part of the character of many listed buildings. Simple early openable rooflights had timber frames, lead-clad kerbs and casements, with the lower edge of the glass left unframed so water could run off, and some survive on Georgian and Regency buildings.[1] Repair usually aims to keep original bars and frames, with replacement glass and glazing chosen to match the original appearance while improving safety and thermal performance where that can be done sensitively. Lead-covered steel patent glazing bars are still manufactured for this purpose.[2]

## Sources

1. Rooflighting — The Building Conservation Directory. https://buildingconservation.com/articles/rooflighting/rooflighting.htm
2. Patent glazing — Designing Buildings Wiki. https://designingbuildings.co.uk/wiki/Patent_glazing
3. Specifying glass for sloped glazing and skylights — The Construction Specifier. https://www.constructionspecifier.com/specifying-glass-for-sloped-glazing-and-skylights/
4. ETFE: Why this Building Material is Gaining Popularity — Architen Landrell. https://www.architen.com/articles/etfe-the-new-fabric-roof