## Key facts

- **Also called:** W truss, Fink trussed rafter
- **Named after:** Albert Fink (1827-1897), bridge patent 9 May 1854
- **Typical domestic span:** Up to about 12 m (39 ft)
- **Connector plates:** Toothed metal plates from 1952 (US); in UK use from 1967
- **US market share:** About two-thirds of residential roofs use manufactured trusses
- **Design standards:** ANSI/TPI 1 (US); Eurocode 5 (Europe)

A **Fink truss**, widely called a **W truss** from the shape of its webs, is a pitched roof truss in which two pairs of diagonal web members run from the top chords down to the bottom chord, forming a W between the eaves. The two top chords act as the rafters, the bottom chord acts as the ceiling joist and tie, and the webs divide each rafter into shorter panels so that light timber can carry the roof over a wide span.[1][2] In Britain and Ireland the prefabricated version is usually called a **Fink trussed rafter**, and by the 1960s it had become the most common configuration for house roofs there.[1]

Under the parent topic of the [roof truss](https://roof.wiki/roof-truss/), the Fink is the everyday workhorse: the type that most people picture when they think of a modern house roof seen from the attic.

## How it differs from other trusses

- **[King post truss](https://roof.wiki/king-post-truss/)** — a single central vertical post with two struts; simple, but its long unsupported rafter panels limit span.
- **[Queen post truss](https://roof.wiki/queen-post-truss/)** — two verticals; leaves a central space but needs heavier members.
- **Fink (W) truss** — no central post; the W-pattern webs triangulate the whole frame, giving short top-chord panels and efficient use of small-section timber.[1]
- **[Attic truss](https://roof.wiki/attic-truss/)** — opens a rectangular room in the middle, at the cost of much heavier chords.
- **[Scissor truss](https://roof.wiki/scissor-truss/)** — slopes the bottom chords for a vaulted ceiling.

The Fink's webs fill the roof void, so the space is suitable only for light storage and services unless the truss is specifically designed as an attic or storage truss (see the 20 psf storage load rule described under [attic truss](https://roof.wiki/attic-truss/)).

## History

The Fink truss began as a bridge truss. Its designer, the German-born American railway engineer **Albert Fink** (1827-1897), worked for the Baltimore and Ohio Railroad from 1849 and patented a truss bridge on 9 May 1854; he later moved to the Louisville and Nashville Railroad, where he built many bridges, including a combination truss with timber compression members and wrought-iron tension members patented in 1867.[3] Fink bridges were widely built between about 1854 and 1875, but only two intact examples survive in the United States, both relocated.[4] In building roofs the form is used upside down relative to many of the bridges, with a lower chord tying the feet of the rafters.[4]

The modern Fink roof truss is a product of the **metal connector plate**. In the United States, A. Carroll Sanford invented a toothed metal truss plate in 1952, and J. Calvin Jureit's Gang-Nail plate of 1955 was the first that needed no supplementary nailing; the Truss Plate Institute was founded in 1960 and published its first design specification that year.[5] Light, plated trusses could be lifted by hand without cranes, and today about two-thirds of US houses are roofed with manufactured trusses.[6] In the UK, the Timber Development Association (now TRADA) published trussed rafter designs from the 1950s, and punched metal plates came into use in 1967.[1]

## Design and dimensions

Fink trusses are designed by truss manufacturers using engineering software, to national standards such as ANSI/TPI 1 in the United States and Eurocode 5 in Europe, for the specific span, pitch, loads and timber grade.[5] Domestic trusses use small-section softwood set at regular layout intervals,[6] and the Fink layout can span up to about 12 m (39 ft) in domestic use.[1]

Each truss is engineered as part of a system. The size and arrangement of the triangles, the grade and species of timber, and the strength of the connector plates are all set by the designer; installers are not permitted to alter them, and site-built trusses are no longer allowed under modern codes.[6]

## Installation

The usual sequence for setting Fink trusses is:[1][6]

1. **Check the wall plates** for level and line; fix plates securely to the walls.
2. **Set the first truss** (often a gable truss), plumb and brace it to the ground or structure.
3. **Lift and space the remaining trusses** at the specified centres, fixing each to the wall plate with nails or truss clips (see [hurricane tie](https://roof.wiki/hurricane-tie/) and [roof-to-wall connection](https://roof.wiki/roof-to-wall-connection/)).
4. **Install temporary and permanent bracing** — diagonal bracing on the underside running from eaves to ridge, longitudinal binders along the ridge and ceiling ties, and any lateral web braces shown on the truss design.
5. **Strap to the walls** to resist wind uplift, standard UK practice since the 1970s.[1]
6. **Sheath or batten the roof**, keeping construction loads such as stacked tiles or sheathing spread across several trusses.

Cutting is generally not allowed except at the rafter tails beyond the bearings.[6] Trusses must be stored flat or upright on bearers and handled carefully, because they can be damaged before they are braced in place, although they are strong once installed.[6]

## Performance and problems

A correctly designed and braced Fink roof is light, economical and quick to erect: an experienced crew can set the trusses of a house in a few hours.[6] Problems seen in practice include:

- **Missing or inadequate bracing**, leading to leaning or "domino" collapse during construction, or to long-term sway in wind;
- **Alterations** — webs cut to fit loft hatches, tanks, ducts or attic conversions, which break the triangulation and can cause sagging (see [sagging roof deck](https://roof.wiki/sagging-roof-deck/));
- **Overloading** of bottom chords by storage or equipment beyond the design ceiling load;
- **Truss uplift**, a seasonal arching of the bottom chord as the warm lower chord dries and the cold top chords absorb moisture, which opens cracks at interior wall-ceiling junctions in cold climates;
- **Moisture and plate corrosion** where the roof space is poorly ventilated or leaks (see [attic condensation](https://roof.wiki/attic-condensation/) and [roof ventilation](https://roof.wiki/roof-ventilation/)).

## Where it is used

Fink trussed rafters are the standard roof structure for new houses in the UK and Ireland — nearly all new domestic roofs there use some form of trussed rafter[1] — and they make up much of the manufactured-truss market that roofs about two-thirds of US houses.[6]

## Sources

1. Trussed rafters — Designing Buildings Wiki. https://www.designingbuildings.co.uk/wiki/Trussed_rafters
2. Types of roof trusses — ClearCalcs. https://calcs.com/blog/types-of-roof-trusses
3. Albert Fink — American Society of Civil Engineers. https://www.asce.org/about-civil-engineering/history-and-heritage/notable-civil-engineers/albert-fink
4. Fink truss — Wikipedia. https://en.wikipedia.org/wiki/Fink_truss
5. Industry Timeline — Structural Building Components Association. https://sbcindustry.com/industry-timeline
6. Introduction to Roof Trusses — Fine Homebuilding. https://finehomebuilding.com/project-guides/framing/introduction-to-roof-trusses