# Fibre-Cement Roofing

> Roofing made of cement reinforced with fibres, mainly as flat slates and corrugated sheets; modern non-asbestos (NT) products use cellulose and synthetic fibres in place of the asbestos of earlier asbestos-cement.

- URL: https://roof.wiki/fibre-cement-roofing/
- Topic: Roofing Materials
- Also known as: fiber cement roofing; fibre cement; fiber cement; NT fibre cement; non-asbestos fibre cement; Eternit
- Regions: Global
- First published: 2026-11-02 · Last reviewed: 2026-11-02
- Cite as: "Fibre-Cement Roofing." roof.wiki. https://roof.wiki/fibre-cement-roofing/

## Key facts

- **Invented:** Patented 1900 by Ludwig Hatschek (Austria); 'Eternit' name from 1903
- **Original mix:** About 90% Portland cement, 10% asbestos
- **Modern fibres:** Cellulose and synthetic fibres (non-asbestos, type NT)
- **Product standards:** EN 492 (slates), EN 494 (profiled sheets)
- **EN 492 freeze-thaw test:** 100 cycles, ≥75% strength retained
- **Slate weight:** About 13–14 kg/m² (2.7 lb/ft²)
- **Corrugated sheet minimum pitch:** About 5°

Fibre-cement roofing covers roof products made from a hardened mix of cement and reinforcing fibres: flat fibre-cement slates, corrugated and profiled sheets, and a smaller range of shakes, shingles and tiles. The material was invented around 1900 as asbestos-cement, and for most of the 20th century its reinforcing fibre was asbestos. Since the recognition of asbestos's health risks, the industry has switched to non-asbestos technology (NT) products that use cellulose and synthetic fibres instead.[4][5] This umbrella article covers the material and its products in general; for the specific products see [fibre-cement slate](/wiki/fibre-cement-slate) and [corrugated fibre-cement sheet](/wiki/corrugated-fibre-cement-sheet), and for the older material see [asbestos-cement roofing](/wiki/asbestos-cement-roofing).

## Composition

European product standards define fibre-cement as consisting mainly of cement, or of calcium silicate formed by a reaction between siliceous and calcareous materials, reinforced with fibres. The fibres may be dispersed discrete fibres, continuous strands or tapes, or nets and webs. The cement must meet EN 197-1, and process aids, fillers and pigments may be added.[1] Products made without asbestos are designated type NT.[1]

In practice, current roofing products are typically Portland cement with a blend of cellulose and synthetic fibres, coloured through the body with pigments and finished with an acrylic coating on the top face and edges.[2] Some corrugated sheets add continuous polypropylene reinforcing strips along certain corrugations to improve strength and resistance to impact.[3]

The original asbestos-cement was about 90 per cent Portland cement and 10 per cent asbestos fibre mixed with water.[4] Cellulose became the main substitute for asbestos when asbestos was phased out.[5]

## Manufacture: the Hatschek process

The Austrian Ludwig Hatschek (1855–1914) patented the material in 1900, under the title "Production of artificial stone slabs with hydraulic binders". He had bought a former paper mill at Schöndorf near Vöcklabruck, Upper Austria, in 1893, and adapted a cardboard-making machine to form the cement-asbestos slurry into thin, strong sheets. He adopted the trade name *Eternit*, from the Latin *aeternus*, "eternal", in 1903.[4] See [Ludwig Hatschek](/wiki/ludwig-hatschek) and [Eternit](/wiki/eternit).

Hatschek's paper-machine principle, building up a sheet from many thin layers of fibre-cement slurry, is still the basis of much fibre-cement production, so the finished material has a laminated structure.[4] The wet sheet is cut to size or moulded into corrugations and then cured, and slates are typically fully compressed to increase their density.[2] One current slate has a density of about 1,850 kg/m³ (115 lb/ft³).[2]

## Products

### Fibre-cement slates

Flat fibre-cement slates are thin, uniform rectangles, often with pre-punched nail holes, made to imitate natural slate at lower cost and weight. In Europe they are covered by EN 492, which applies to slates and fittings up to 850 mm (33½ in) high for overlapping roofing and for wall and ceiling finishes.[1] A typical example is 400 × 400 mm (15¾ × 15¾ in) and 4 mm (0.16 in) thick. Laid at about 10 slates per square metre, it weighs about 13.4 kg/m² (2.7 lb/ft²), about half the weight of many natural slate roofs. It needs a minimum pitch of 30° in moderate exposure and 35° in severe exposure.[2]

### Corrugated and profiled sheets

Corrugated fibre-cement sheets, made to EN 494, are used on farm, industrial and agricultural buildings, at low pitches. One "Profile 6" type sheet is 1,086 mm (42.8 in) wide with a cover width of 1,016 mm, 6.5 mm (¼ in) thick, with corrugations 146.5 mm apart and 47.6 mm deep. It weighs about 17–18 kg/m² (3.5–3.7 lb/ft²) and can be laid as low as 5°, with 150 mm (6 in) end laps, 70 mm side laps and purlins at up to 1,375 mm (4.5 ft).[3] Such sheets are classed under EN 494 and are expected to last more than 50 years.[3]

### Shakes, shingles and tiles

In North America, fibre-cement shakes and slates were sold as fire-resistant substitutes for wood shakes, and several early non-asbestos products performed badly. A class action over one maker's fibre-cement shakes, installed on an estimated 30,000 homes, was settled for a total of US$140 million, with the final phase approved in November 2003.[7] In 2002 another manufacturer settled a US class action over its fibre-cement roof shakes and slates, offering replacement costs to owners whose roofs showed damage or premature deterioration.[6]

## Performance

### Durability tests

EN 492 requires NT slates to pass four durability tests: 100 freeze-thaw cycles, 50 heat-rain cycles (checking for cracks, delamination, warping and bowing), 56 days in warm water at 60 °C (140 °F), and 50 soak-dry cycles. In the freeze-thaw, warm-water and soak-dry tests, slates must keep at least 75 per cent of their original strength.[1] Slates are also graded by minimum bending moment, for example 30 N·m/m for slates up to 350 mm high and 40 N·m/m up to 450 mm.[1]

### Fire

Fibre-cement is largely non-combustible. Some products are classified A1 or A2 for reaction to fire, though not all products test equally well.[5] One slate is classed A2-s1,d0 under EN 13501-1,[2] and one corrugated sheet Class 1 under BS 476-7.[3] See [EN 13501-5](/wiki/en-13501-5).

### Thermal and chemical behaviour

Fibre-cement expands only slightly with temperature, about 8 × 10⁻⁶ per °C, or 0.08 mm per metre for a 10 °C change.[2] It is alkaline, so it is compatible with most building materials but not with those vulnerable to alkaline attack. Aluminium gutters and flashings that receive runoff from it should be protected with bituminous paint, and lead flashings should be treated with patination oil on the day they are fixed to prevent white lead-carbonate staining.[2]

### Lifespan

Manufacturers typically state a durability of 30 years for slates and more than 50 years for corrugated sheets, with colour stability of about 10 years for coloured slates. Painted sheets may need recoating every 10–20 years.[2][3]

## Failure modes

- **Delamination and cracking.** Because the material is built up in thin layers, poor-quality or early NT products could split into layers, crack or curl, especially under repeated freezing and wetting. This is the failure mode targeted by the EN 492 freeze-thaw and heat-rain tests.[1][6][7] See [freeze-thaw damage](/wiki/freeze-thaw-damage).
- **Efflorescence.** White salt deposits can form on the surface, especially when slates are stored wet. Water trapped between stacked slates causes efflorescence staining, so slates should be kept dry, and cutting dust should be removed promptly.[2]
- **Moss and lichen** on unprotected or worn surfaces; acrylic coatings reduce growth.[2] See [roof moss](/wiki/roof-moss) and [lichen on roofs](/wiki/lichen-on-roofs).
- **Surface erosion** from prolonged chemical exposure.[2]
- **Fragility.** Fibre-cement sheets are a well-known fall-through hazard. Before the early 1990s, asbestos-cement sheets were made and sold as fragile.[8] Modern corrugated sheets can achieve Class B or C non-fragility when new, yet manufacturers still advise treating an installed fibre-cement roof as fragile and using crawling boards.[3] See [fragile roof](/wiki/fragile-roof).

## Replacement of asbestos-cement

From the 1970s, asbestos exposure was widely recognised as a cause of asbestosis and mesothelioma, and its use was progressively banned, with cellulose taking its place in fibre-cement.[5] Fibre-cement NT sheets and slates are now used as like-for-like replacements for old asbestos-cement roofing, with corrugated sheets made in the familiar profiles.[3] Removing asbestos-cement is a regulated specialist activity in many countries. See [history of asbestos-cement roofing](/wiki/history-of-asbestos-cement-roofing).

## Regional practice

Fibre-cement slates and sheets are made and used worldwide, and in Europe they are governed by the common standards EN 492 and EN 494.[1][3] For regional variants see [shifer](/wiki/shifer), the corrugated asbestos-cement and fibre-cement sheet of the former Soviet Union, [Korean asbestos-slate roofs](/wiki/korean-asbestos-slate-roofs), and [Everest Industries](/wiki/everest-industries) in India.

## Sources

1. EN 492:2012+A2:2018 Fibre-cement slates and fittings – Product specification and test methods — CEN (via iTeh Standards). https://standards.iteh.ai/catalog/standards/cen/6c4f2ba7-2fbf-4465-84de-f5c3977d98ee/en-492-2012a2-2018
2. Fibre cement slate technical data sheet — ESI Building Design (manufacturer data sheet). https://cms.esi.info/Media/documents/78960_1560250701669.pdf
3. EUROSIX Fibre Cement Profiled Sheets datasheet — FarmFit / Briarwood Landini. https://cdn.shopify.com/s/files/1/0653/7461/7853/files/FF_Fibre_Cement_Datasheet.pdf
4. Ludwig Hatschek — Wikipedia. https://en.wikipedia.org/wiki/Ludwig_Hatschek
5. Fiber cement — Wikipedia. https://en.wikipedia.org/wiki/Fiber_cement
6. Hardie Settles Class-Action Suit Over Roof Shakes — BuildingGreen. https://www.buildinggreen.com/node/11162
7. American Cemwood — Lieff Cabraser Heimann & Bernstein. https://www.lieffcabraser.com/defect/cemwood
8. Rooflights and non-fragility – guidance from NARM — National Association of Rooflight Manufacturers. https://narm-3k7.pages.dev/rooflights-and-non-fragility-guidance-from-narm/