# Coated Copper (Lead-Coated and Tin-Zinc-Coated)

> Copper sheet hot-dipped in lead alloy or, today, a tin-zinc alloy so that it weathers grey instead of green and does not stain nearby stone, used for roofing, flashings and gutters.

- URL: https://roof.wiki/coated-copper/
- Topic: Roofing Materials
- Also known as: lead-coated copper; LCC; tin-zinc coated copper; TZ-coated copper; terne-coated copper; tinned copper
- Regions: North America, Europe
- First published: 2026-11-02 · Last reviewed: 2026-11-02
- Cite as: "Coated Copper (Lead-Coated and Tin-Zinc-Coated)." roof.wiki. https://roof.wiki/coated-copper/

## Key facts

- **Traditional coating:** Lead with 3–4% tin, hot-dipped (ASTM B101)
- **Modern replacement:** About 50% tin / 50% zinc alloy coating
- **Lead-coated copper introduced:** 1930s, United States
- **US lead-coated production ended:** End of September 2004 (last major producer)
- **Example coated weight:** 16 oz copper → at least 17.3 oz/ft² coated
- **Main reason for use:** Grey weathering, no green runoff staining
- **Soldering:** Lead-free solder, tin-loaded flux, pre-tinning

Coated copper is architectural copper sheet that has been hot-dipped in a protective metal coating, so that the exposed surface is the coating rather than the copper itself. It keeps copper's strength, workability and solderability, but weathers to a soft grey like lead or zinc instead of turning brown and then green, and it does not shed copper-bearing runoff that stains masonry, stone and painted surfaces.[3][4] The traditional product was **lead-coated copper**, made to ASTM B101; since lead coatings were withdrawn from the US market in the 2000s, **tin-zinc-coated copper** has largely replaced it.[4][1]

Coated copper sits between plain [copper roofing](/wiki/copper-roofing) and [lead roofing](/wiki/lead-roofing): it has the light weight and long panel lengths of copper with the colour and appearance of lead. It should not be confused with [terne plate](/wiki/terne-plate) or [terne-coated stainless steel](/wiki/terne-coated-stainless-steel), where the same kinds of coating are applied to steel.

## Lead-coated copper

### Introduction and use

Lead-coated copper was introduced in the United States in the 1930s by the Revere Copper and Brass Company. An early documented use was the 1935 re-roofing of the main block of the Schuyler Mansion in Albany, New York.[3] The sheet was made by dipping copper twice, first in a lead-tin alloy and then in pure lead, and then rolling it.[3]

It became a standard material for flashings and valleys on slate roofs, where it resisted damage from broken slate fragments, and on wood-shingle roofs, where flashings hidden under the shingles could not be painted.[3] Because the copper itself was not exposed to the weather, it did not corrode in the usual way and did not stain neighbouring materials.[3] ASTM B101 also covers its use for roofing, gutters and downspouts.[1]

### ASTM B101

ASTM B101, *Standard Specification for Lead-Coated Copper Sheet and Strip for Building Construction*, covers lead-coated copper in flat lengths or coils, with the lead applied by hot dipping. It is intended for roofing, flashing, gutters, downspouts and general exterior sheet-metal work, but not for electrical use, decorative or ornamental work, or wall panels.[1] Its companion standard for uncoated copper is [ASTM B370](/wiki/astm-b370).[1]

Under the 2012 edition, the coating is a lead alloy containing 3.0–4.0 per cent tin, with small limits on silver, copper, arsenic, antimony, zinc, iron, bismuth and phosphorus. The copper may be soft (O60), eighth-hard (H00) or quarter-hard (H01), and sheet from 8 to 48 oz/ft² is covered.[2] The coating adds weight. For nominal bare copper of 12, 16, 20 and 24 oz/ft², the minimum coated weights are 13.2, 17.3, 21.2 and 25.0 oz/ft² respectively, roughly 1 to 1.3 oz/ft² (about 300–400 g/m²) of lead alloy in total.[2] In metric terms, 16 oz copper is about 0.55 mm (0.0216 in) thick.

### Withdrawal

Lead-bearing building coatings came under pressure from limits on lead in stormwater, air and soil, and from the wider removal of lead from paint and solder.[5] The last major US producer of lead-coated copper roofing ended production at the end of September 2004, and replaced it with a tin-zinc-coated product of similar appearance.[4]

## Tin-zinc-coated copper

The main modern replacement is copper hot-dipped in an alloy of roughly 50 per cent tin and 50 per cent zinc.[4] It was developed alongside similar lead-free coatings for steel. On steel, a patented zinc-tin coating of about 50 per cent zinc was designed to match the corrosion resistance of the old lead-tin terne and to weather to an even grey patina without blotching or the spangled look of hot-dip galvanising; its makers also described applying it to copper, bronze and other metals.[5]

Tin-zinc-coated copper is installed with the same seams, cleats and details as uncoated copper. Points of difference are mainly in soldering:[6]

- Surfaces must be clean, dry and free of oxides, which can be removed by light abrasion without taking off the coating; stripping the coating can cause corrosion and appearance problems.
- Only lead-free solder is recommended, since lead in the solder lowers its melting point, reduces flow and weakens the seam.
- A tin-loaded flux is used; fluxes containing free hydrochloric or phosphoric acid are avoided.
- Surfaces are pre-tinned before locks are closed. Locks are about ¾ in (19 mm) wide, and soldering coppers are preferred to open-flame torches.
- Soldering should be completed within about four hours of exposure; seams left out longer, and especially overnight when dew can form, should be opened, cleaned and re-fluxed.

See [soldering sheet-metal roofing](/wiki/soldering-sheet-metal-roofing).

## Comparison with terne and lead

The lead coating on copper differed from traditional terne, the lead-tin alloy used on steel roofing plate. Terne has been described as about 70 per cent lead and 30 per cent tin, and trade sources put traditional terne coatings at close to 80 per cent lead, whereas the ASTM B101 coating is almost pure lead with only 3–4 per cent tin.[2][4][5] In the early 1990s, reports of reddish discoloration on lead-bearing roofs were linked to lower sulphur levels in the air after flue-gas controls.[5] The lead-free zinc-tin coatings were tested on steel, where they lasted 5,164 hours in ASTM B117 salt spray without red rust, against a typical benchmark of about 2,000 hours for roofing materials.[5]

## Appearance and weathering

Fresh lead- and tin-zinc-coated copper is a bright or matt silver-grey. Over months to years the coating weathers to a duller, darker grey, similar to weathered lead or zinc.[5] Because the copper is sealed under the coating, the sheet does not develop the green [copper patina](/wiki/copper-patina) and does not wash copper salts onto the materials below. This is the main reason it is chosen next to stone, light-coloured masonry and painted trim (see [copper runoff staining](/wiki/copper-runoff-staining)).[3]

At cut edges, scratches and fasteners, the copper base can show through. Small areas of exposed copper are generally tolerated, but deep abrasion during forming or cleaning should be avoided.[6]

## Uses

Typical applications include:

- **Flashings and valleys** on slate, tile and wood roofs, where the grey colour blends with the roofing and runoff staining is unwanted.[3]
- **Gutters, downspouts and conductor heads** on stone and brick buildings.[1]
- **Roofing and cladding** with standing-seam, batten-seam or flat-seam panels, where a lead-like grey is wanted with copper's lighter weight and longer panel lengths.[1][4]
- **Restoration** of earlier lead-coated copper and of buildings originally roofed in lead, especially in North America.[3]

## Related coated copper products

Factory pre-oxidised and pre-patinated copper also give an immediate finished colour, but by chemically forming copper oxides or patina on the copper itself rather than adding a separate metal coating; [pre-weathered zinc](/wiki/pre-weathered-zinc) is the zinc equivalent. The same lead-free tin-zinc coating technology is applied to steel, where it replaced traditional terne.[5]

## Sources

1. ASTM B101-22 Standard Specification for Lead-Coated Copper Sheet and Strip for Building Construction — ASTM International (via GlobalSpec). https://standards.globalspec.com/std/14621930/astm-b101-22
2. ASTM B101-12 (sample) — ASTM International (via iTeh Standards). https://cdn.standards.iteh.ai/samples/80225/9f0b8817dcc34a2cb4e590d45cc4f161/ASTM-B101-12.pdf
3. Metals in America's Historic Buildings, Part 1 — US National Park Service. https://www.nps.gov/orgs/1739/upload/book-metals-in-america-part-1.pdf
4. Revere Ends Lead-Coated Copper Roofing — BuildingGreen (Environmental Building News). https://www.buildinggreen.com/node/11292
5. Leaving Lead Behind — Roofing Contractor. https://www.roofingcontractor.com/articles/84966-leaving-lead-behind
6. FreedomGray Soldering — Revere Copper Products. https://reverecopper.com/wp-content/uploads/2021/07/FreedomGray-Soldering.pdf