# Box Gutter (Built-In Gutter)

> A rectangular gutter built into the roof structure, cornice or the valley behind a parapet, rather than hung from the eaves, and lined with sheet metal or a membrane; a common leak point that needs overflows.

- URL: https://roof.wiki/box-gutter/
- Topic: Roof Components
- Also known as: built-in gutter; internal gutter; parapet gutter; Yankee gutter; Philadelphia gutter; valley gutter; box gutters; concealed gutter
- Regions: Global, North America, Europe, Oceania
- First published: 2026-11-02 · Last reviewed: 2026-11-02
- Cite as: "Box Gutter (Built-In Gutter)." roof.wiki. https://roof.wiki/box-gutter/

## Key facts

- **Location:** Inside the roof line: cornices, behind parapets, between roofs
- **Linings:** Copper (16–20 oz), lead, zinc, stainless steel, aluminium, EPDM or butyl
- **Minimum width:** 300 mm (12 in) commercial/NZ; 200 mm (8 in) domestic in Victoria, Australia
- **Typical falls:** 1:200 to 1:40 (Australia); at least 1:100, preferably 1:60 (New Zealand)
- **Overflow:** Required: rainhead weir, side overflow or high-capacity sump
- **Design rainfall:** 1% AEP (100-year ARI) in Australia; BRANZ advises at least 200 mm/h in NZ
- **Service life:** 60–100+ years for well-maintained historic copper-lined gutters

A box gutter, or built-in gutter, is a rectangular or trough-shaped gutter formed within the building envelope rather than hung outside it. It may sit inside a cornice at the eaves, behind a parapet wall, or in the valley between two roofs, and it is drained by outlets to downpipes or conductor heads. It is usually a timber or steel trough lined with a watertight sheet of metal or membrane.[1][3] In North America the historic forms are also called Yankee, Philadelphia or simply built-in gutters.[1]

Box gutters are a sub-type of rain gutter, but they work in a very different way from eaves-hung gutters such as the K-style and half-round types. A hung gutter that overflows spills water outside the wall. A blocked or undersized box gutter overflows into the roof, walls or ceilings. That is why modern codes treat box gutters as a high-risk detail and require overflows, generous falls and careful sizing.[2][3]

## Forms

- **Cornice (Yankee) gutters.** A trough built into the top of a timber or masonry cornice, so the gutter is hidden behind the moulding. These were first adopted in North America in the 18th century on high-style Georgian and Federal buildings, usually institutional or commercial, and drain through internal or external leaders.[1]
- **Parapet gutters.** A gutter running along the inside of a parapet wall at the foot of a pitched roof.
- **Valley or internal gutters.** A gutter between two pitched roofs or between a roof and an abutting wall, entirely inside the building's footprint.[3]

## Lining materials

Early American built-in gutters were plain wooden troughs rubbed with linseed oil or painted, with lead wedges sealing corners and seams. Sheet lead later lined the troughs and allowed wider gutters, and by the late 18th century copper had become a popular lining.[1] Tin and terne-coated steel linings were also widely used, but when they fail they let water rot the timber.[1]

Modern guidance sets minimum lining thicknesses. New Zealand's BRANZ lists:[3]

| Lining | Minimum thickness |
|---|---|
| Aluminium (5000 series, O temper) | 0.9 mm (0.035 in) |
| 316 stainless steel | 0.45 mm (0.018 in) |
| Copper | 0.5 mm (0.020 in) |
| Zinc (EN 988) | 0.7 mm (0.028 in) |
| Butyl or EPDM, up to 1.0 m wide | 1.0 mm (0.039 in) |
| Butyl or EPDM, over 1.0 m wide | 1.5 mm (0.059 in) |

BRANZ does not accept galvanized steel or ordinary Z275 or AZ150 coated steel for internal gutters. It requires metal gutters to have welded joints with no fixings through the bottom or sides. Membranes should be laid in one continuous length along the gutter with no cross joints.[3] For restoring historic copper-lined gutters, 16 or 20 oz copper (about 0.55 or 0.68 mm) is used depending on the gutter's size.[1]

## Design rules

Because failure is costly, box gutters are sized more conservatively than eaves gutters.

**Width and depth.** Victoria's building authority requires a minimum sole width of 200 mm (7.9 in) for domestic and 300 mm (11.8 in) for commercial box gutters. Its deemed-to-satisfy sizes are 200, 300, 375, 450, 525 and 600 mm, and a gutter must not narrow towards its outlet.[2] New Zealand guidance calls for at least 300 mm (11.8 in) width, 70 mm (2.8 in) depth and 20 mm (0.8 in) extra freeboard. Wider gutters are recommended so people can walk in them for maintenance.[3]

**Fall.** Victorian practice allows grades of 1:200, 1:150, 1:100 and 1:40.[2] New Zealand requires at least 1:100 and recommends 1:60. Metal gutters with less than about 1.5° of fall may not meet manufacturers' warranty conditions.[3]

**Rainfall intensity.** Australian box gutters are sized for a 1 per cent annual exceedance probability, the 100-year average recurrence interval storm, under AS/NZS 3500.3.[2] BRANZ recommends designing for at least 200 mm (7.9 in) per hour at the 10-minute intensity, double the minimum in the New Zealand code.[3]

**Outlets.** BRANZ recommends at least two outlets on each gutter run, placed at the lowest points so that deflection does not leave an outlet high. Downpipes should be no more than 12 m (39 ft) apart, so a regularly spaced gutter runs no more than 6 m (20 ft) to each outlet. Internal downpipes should be avoided where possible.[3] Australian design flows per downpipe must fall between 3 and 16 L/s.[2]

## Overflows

Overflow provision is the most important safety feature of a box gutter. Every gutter must be able to discharge outside the building if its outlet blocks:

- **Rainhead with weir.** The gutter discharges over a weir into an open rainhead whose overflow is lower than the gutter sole. In Victoria the weir spans the full rainhead width and sits 25 mm (1 in) below the gutter sole.[2][3]
- **Side overflow sumps.** These are at least 400 mm (16 in) long, with a side channel discharging through the wall.[2]
- **High-capacity overflow sumps.** These are 600 mm (24 in) long and at least 150 mm (6 in) deep in combination with the overflow device.[2]

In New Zealand the top of an overflow must be at least 50 mm (2 in) below the top of the gutter, and its cross-sectional area must be no less than that of the downpipes it serves. Overflows should discharge where they are easily seen, such as beside a doorway, to give early warning of a blockage.[3] Overflows must discharge to open air, clear of neighbouring properties and public areas.[2]

## Thermal movement and support

Long metal gutters expand and contract. Victorian practice requires expansion provision where fixed points are more than 6 m (20 ft) apart, with details showing a 50 mm (2 in) expansion space. Lap joints are 25 mm (1 in), sealed and fastened in the direction of flow.[2] BRANZ recommends an expansion joint at the upper end of each gutter section, and at abutments, with no fixings through the gutter to restrain it.[3] The gutter must be continuously supported, or carried on brackets no more than 750 mm (30 in) apart for gutters narrower than 450 mm. The support must carry the gutter full of water plus foot traffic.[2]

## Common failures

Box gutters are a well-known source of leaks. Typical causes are:

- too little fall, outlet capacity or overflow, or no allowance for movement;[3]
- the wrong lining material for the exposure or for contact with treated timber;[3]
- blockage by leaves, hail or snow, and ice damming in winter;[1][3]
- pinhole corrosion and cracking at folds and joints from repeated expansion;[1]
- damage from falling branches.[1]

The first signs of a leaking cornice gutter are often peeling paint and rot in the soffit below. Other signs include stains, mildew or decaying masonry, water in the attic, and damaged plaster under the gutter.[1]

## Inspection, maintenance and restoration

Box gutters should be cleaned as often as needed and inspected by a competent roofer. Leaks are cheaper to fix early.[1] New gutters should be flood-tested before internal finishes go in, and concealed downpipes pressure-tested before they are enclosed.[3] Ice should not be chipped out with sharp tools, and roofing tar or other bituminous products should never be used to patch metal linings.[1]

The restoration sequence for a historic copper-lined cornice gutter is:[1]

1. Remove the old lining and about 2 ft (0.6 m) of the roof covering above the gutter curb.
2. Repair rotted framing by sistering or scarfing in new timber.
3. Replace the gutter bottom with cedar or kiln-dried treated plywood.
4. Lay the lining system: self-adhered membrane where needed, felt, a rosin-paper slip sheet, and then copper.
5. Re-lay the roof covering with about 2 ft (0.6 m) of membrane or copper flashing beneath it.
6. Repair the cornice mouldings and woodwork.

A well-detailed, regularly maintained built-in gutter can last 60 to 100 years or more, depending on the lining.[1] New Zealand's code requires at least 15 years of durability with normal maintenance, but BRANZ notes that in practice an internal gutter should last as long as the roof cladding.[3]

## Sources

1. Built-in Gutters Should Be Carefully Inspected, Restored and Maintained — Roofing Magazine. https://roofingmagazine.com/built-in-gutters-should-be-carefully-inspected-restored-and-maintained/
2. Plumbing Practice Note RP-02: Box Gutters (current 1 Aug 2023) — Victorian Building Authority. https://www.bpc.vic.gov.au/__data/assets/pdf_file/0009/22005/Plumbing_RP-02_Box-Gutters_CURRENT_01-Aug-2023.pdf
3. BU556 Internal Gutter Design — BRANZ. https://prod.branz.co.nz/documents/3986/BU556-Internal-gutter-design.pdf