# Aluminium Tile Roofing

> Aluminium roof panels or shingles formed to imitate clay or concrete tile profiles, weighing a small fraction of real tile and used for re-roofing and in coastal and seismic regions.

- URL: https://roof.wiki/aluminum-tile-roofing/
- Topic: Roofing Materials
- Also known as: aluminum tile roofing; aluminum tile roof; aluminium roof tiles; aluminum barrel tile; metal tile roofing (aluminum); tile-look aluminum panels
- Regions: North America, Global
- First published: 2026-11-02 · Last reviewed: 2026-11-02
- Cite as: "Aluminium Tile Roofing." roof.wiki. https://roof.wiki/aluminum-tile-roofing/

## Key facts

- **Material:** 3003 or 3105 aluminium, about 0.028–0.030 in (0.70–0.76 mm)
- **Typical panel:** 21.5–44 in (546–1,121 mm) wide, one or more tile courses deep
- **Installed weight:** About 0.59–0.71 psf (2.9–3.5 kg/m²)
- **Real tile, for comparison:** About 8–19 psf (39–93 kg/m²) clay; 12 psf (59 kg/m²) concrete
- **Fixing:** Stainless-steel screws with sealing washers, often concealed
- **Minimum slope:** 3:12 (14°) to 4:12 (18°) depending on underlayment
- **Fire classification:** Class A or B by assembly with specified underlayments

Aluminium tile roofing is a steep-slope metal roof whose panels are pressed into the shapes of clay or concrete roof tiles. The shapes include the rolling barrel or S-profile of Spanish and Mission tile and the low, flat profiles of some concrete and Mediterranean tiles. Instead of hundreds of separate fired units on battens, the roof is made of fairly large painted aluminium panels, each representing a row or several rows of tiles. They lap and lock together and are fixed with screws.[1][2][6] The system belongs to both the aluminium metal-shingle family and the broader group of metal roof tiles, which also includes pressed steel and stone-coated steel tile panels.

It is used mainly for its light weight. A tile look can be put on a house framed for asphalt shingles, and a heavy tile roof can be replaced without the cost of strengthening the frame.

## How it differs from related coverings

- **Compared with clay and concrete tile.** Real tiles are thick, heavy and brittle. They depend on their own weight, battens, clips and sometimes mortar or foam to stay in place, and they can crack under foot traffic or impact. Aluminium tile panels are thin, ductile and mechanically fastened. Their tile shape is a pressed relief rather than solid fired material.
- **Compared with other aluminium shingles.** Slate and shake designs are usually small units nailed through a concealed strip. Tile designs are larger, deeper-formed panels that are generally screwed down because of their size and profile.[1][2]
- **Compared with stone-coated steel tile.** Stone-coated panels use a steel base with bonded granules for texture. Aluminium tile panels rely on paint and pressing, and they weigh less.

## Weight savings

Typical dead loads in a common reference table are about 19 psf (93 kg/m²) for Spanish clay tile, 12 psf (59 kg/m²) for concrete tile and 6 psf (29 kg/m²) for lightweight clay tile, against 2 to 3 psf (10 to 15 kg/m²) for asphalt or fibreglass shingles.[3] Other references put clay tile at about 8 psf (39 kg/m²).[4] Two ICC-ES-evaluated aluminium tile systems weigh:

- 0.62 to 0.71 psf (3.0 to 3.5 kg/m²) installed for a 0.030 in (0.76 mm) panel 44.1 in (1,121 mm) wide, made in single-course, two-course and custom lengths.[1]
- About 0.59 psf (2.9 kg/m²) for a 0.0276 in (0.70 mm) concealed-fastener tile panel 21.5 in (546 mm) wide, with an 18 in (457 mm) exposure and lengths of 16.25 to 91.25 in (413 to 2,318 mm).[2]

That is roughly one-twentieth to one-thirtieth of the weight of a clay or concrete tile roof. Rafters are sized by dead load, so changing between tile and lighter roofing alters the structural requirements. When heavy tile is added to a house, building officials often require an engineer's review.[4] Going the other way, from tile to aluminium, removes much of the permanent load from the frame. It also reduces the roof mass that the structure must resist in an earthquake.

## Materials and finish

Evaluated panels use aluminium alloy 3105, or 3003, to ASTM B209, in H24 temper.[1][2] The exposed face is finished with fluoropolymer (PVDF) paint over a primer. One report specifies 0.8 mil (20 µm) of PVDF over 0.2 mil (5 µm) of primer, and another requires at least 1.0 mil (25 µm) on the top surface.[1][2] Colours imitate terracotta, buff, brown and grey tiles. Trim and ridge pieces in one system are made from a stronger 5182 alloy at least 0.022 in (0.56 mm) thick.[2]

## Installation

The two evaluated systems show the typical methods:

- **Through-screwed panels.** The 44 in panels are fixed with No. 9-15 stainless-steel screws with bonded sealing washers. Vertical laps use 2.5 in (64 mm) screws at each course at no more than 14 in (356 mm) centres. Field screws are placed in every other valley of the profile at up to 14 in (356 mm), or in every valley at up to 7 in (178 mm), depending on the wind design.[1] Allowable uplift is 66.1 or 93.7 psf (3.2 or 4.5 kPa), depending on the screw spacing.[1]
- **Concealed fixing.** The narrower tile panel is laid from right to left with No. 10 stainless screws and butyl-and-metal washers hidden by the next course. It has allowable uplift pressures from about 53 to 142.5 psf (2.5 to 6.8 kPa).[2] It may be fixed over spaced sheathing under set conditions, as well as over solid plywood, and prefabricated flashings are used at penetrations.[2]

Underlayment and ice barrier follow the code for metal roof coverings. Minimum slopes are 3:12 (about 14°) for one system, and 3:12 with a self-adhered underlayment or 4:12 (about 18°) with a mechanically fastened underlayment for the other.[1][2] Re-roofing over existing asphalt shingles is permitted for some tile products where the code allows, with old flashings removed and replaced.[2]

## Fire and wildfire

Aluminium does not burn, but because it melts at a relatively low temperature it is not accepted as a Class A covering by default. It has to be tested as an assembly with an extra fire-resistant layer.[5] In the reports cited, a large tile panel reaches Class A over two layers of a specified fire-resistant roof-deck underlayment and Class B over one.[1] The concealed-fastener tile reaches Class A or B with a named underlayment and is non-classified over a self-adhered underlayment.[2]

Tile-shaped roofs of any material leave openings at the eaves and ridge where birds can nest and embers can enter. Wildfire guidance recommends closing these gaps with eave and ridge closures ("bird stopping") and keeping debris off the roof.[5]

## Coastal use and durability

Aluminium forms a protective oxide film and does not rust, which suits salt-laden coastal air. The panels must still be isolated from copper and bare steel, and fixed with stainless-steel screws, as the evaluation reports specify, to avoid galvanic corrosion.[1][2] The factory PVDF finish needs no painting or sealing.[1][6]

Common problems include:

- dents in the raised "tile" crowns from foot traffic. Installers walk in the pans or on the screw lines.
- sealing washers that age at exposed screws.
- leaks where a hip, valley or wall junction breaks the tile pattern and needs field-formed flashing.

## Sources

1. ESR-1360: Metal Roof Panels and Shingles — ICC Evaluation Service. https://icc-es.org/wp-content/uploads/report-directory/ESR-1360.pdf
2. ESR-1790: Metal Roof Panels and Shingles — ICC Evaluation Service. https://icc-es.org/wp-content/uploads/report-directory/ESR-1790.pdf
3. Weights of Building Materials (GE-1) — Boise Cascade. https://cdn.mediavalet.com/usva/boisecascade/uExXiLUi6k6tu7uPLPdLkw/fWr355cu9U2E74gm_8BDYA/Large/GE-1_Weights_Building_Materials.pdf
4. Q&A: Heavy Roof Loads From Tile — Journal of Light Construction. https://www.jlconline.com/how-to/roofing/q-a-heavy-roof-loads-from-tile_o
5. Fire-Resistant Roofs — Fire Safe Marin. https://firesafemarin.org/home-hardening/roof/
6. Types of Aluminum Roofing — interlockroofing.com. https://www.interlockroofing.com/kb/types-of-aluminum-roofing/